9
CV
Discription
6021 Value DCC Value
01
Adresse
01 - 80 (55)
1 - 127 (3)
CV 29/Bit5 =0
02
PoM Minimum Speed
—
0 - 255 (25)
03
PoM Acceleration delay
01 - 63
0 - 255 (15)
04
PoM Braking delay
01 - 63
0 - 255 (15)
05
PoM Maximum speed
01 - 63
0 - 255 (255)
08
Factory Reset / Manufacturer Recognition
08
08 (131)
13
PoM Functions F1 - F8 in analog operation
—
0 - 255 (0)
14
PoM Functions F9 - F15 and lights in analog operation
—
0 - 255 (1)
17
Extended address (upper part CV29 Bit 5 = 1)
—
193 - 255 (192)
18
Extended address (lower part CV29 Bit 5 = 1)
—
0 - 255 (128)
19
Multiple Unit Address
—
0 - 255 (0)
21
PoM Functions F1 - F8 on Multiple Unit
—
0 - 255 (0)
22
PoM Functions F9 - F15 and lights on Multiple Unit
—
0 - 255 (0)
29
Bit 0: Reversing direction
Bit 1: Number of speed levels 14 or 28/128
Bit 2: DCC operation with braking area
Bit 5: Address length 7 Bit / 14 Bit
—
0 / 1 (0)*
0 / 2 (2)*
0 / 4 (4)*
0 / 32 (0)*
mfx: Changes to the settings on the mfx decoder can be done with the buttons on
the 60213/60214 Central Station. The procedure can be
found in the help file on the Central Station.
( ) Values = factory settings
DCC: programming on the programming track by means of CV programming, programming with PoM (Program on the Main); this must be supported by the
controller you are using.
*
The values for the desired setting must be added! Example: The number of speed levels 28/128 = 2 + DCC operation with a braking route = 4, results in
the value = 6
5.
Содержание 55175
Страница 1: ...Modell des Adlers 55175 ...
Страница 3: ...3 1 2 1 3 2 1 3 ...
Страница 4: ...4 1 2 1 ...
Страница 5: ...5 1 ...
Страница 16: ...16 8 7 6 2 3 4 5 1 ...
Страница 17: ...17 8 1 Fett 3 2 ...
Страница 19: ...19 9 ...