3
INSTALLATION
Service Connections
ELECTRICAL CHARACTERISTICS
ELECTRICAL (ALTAIR II - 4) 60 Hz
Voltage
pH
kW
Amps
208
1
8
38.5
240
1
8
33.3
208
3
8
22.2
240
3
8
19.3
480
3
8
9.6
ELECTRICAL (ALTAIR II - 6) 60 Hz
Voltage
pH
kW
Amps
208
1
9.8
47.1
240
1
9.8
40.8
208
3
9.8
27.2
240
3
9.8
23.6
480
3
9.8
11.8
24 [610]
19 [483]
3.88
[98]
ALTAIR II-4
15.38 [391]
ALTAIR II-6
22.38 [568]
4.75 [121]
2 [51]
20 [508]
FRONT VIEW
6 [152]
ALTAIR II-4
26.25 [667]
ALTAIR II-6
33.25 [845]
2 [51]
30.75 [781]
28.75 [730]
17.75 [451]
PULL OUT
SERVICE
DRAWER
DOOR IN
OPEN POSITION
2 [51]
22 [559]
4.75 [121]
SIDE VIEW
STEAM VENT
WATER IN
1.5 [38]
2 [51]
8.5 [216]
3.25
[83]
REAR VIEW
DIMENSIONS ARE IN INCHES [MM]
Figure 1
ALTAIR II-4 AND ALTAIR II-6
WATER SUPPLY & DRAIN
Good quality water feed is the responsibility of the owner. Water quality must
be within the following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm pH: 7.0 - 8.5
Silica: <13 ppm
Chlorides: <25 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system
designed to meet your water quality conditions.
Pressure:
25(min)-50(max) PSI
Connections: Trough drain: 1/2 MNTP Drain out: 1” FNPT Water: 3/4” male
garden hose
The drain piping must consist of temperature resistant material, greater than
160°F, and be of adequate diameter not to cause flow restriction. Improper
materials may deform and cause restrictions, thus affecting performance.
Appliance to be installed with backflow protection according to federal, state or
local codes.
NOTES
Each single compartment has one rear drain connection
4” clearance left mandatory, right and rear is recommended.
Location near a floor drain is recommended.
Refer to electrical characteristics chart for voltage requirements of each
steamer.
Each compartment requires separate electrical & water connection.