background image

3

 EN

2.0 Installation

Ensure that the mains supply is isolated before proceeding

2.1  Decide on the position the fan is to be 
sited; it must be a minimum of 2.3m from 

the floor to the lowest point on the fan. (A 
shorter 150mm long downrod is supplied 
with the fan if required. Refer to the 

section on installing the shorter downrod).
2.2  Stick a vibration damper on the 

bracket of the J-hook. Fix the ceiling 
J-hook (supplied) firmly to a timber joist or 
concrete ceiling with the screws supplied 

(or similar). Ensure that the fixing bracket 
in the ceiling is able to support a hanging 

weight of 15kg minimum. (Fig A)
2.3  Fit the three blades to the fan body. 
(Fig B)

2.4  Hang the fan on the hook with the 
safety wire, then hook up the fan on the 

black rubber roller making sure that all 
wires are clear.
2.5  Connect supply wires to the fan 

using the terminal block at the top of the 
downrod. (Fig C, next page)

2.6.  Secure upper canopy with screws fitted to cover the wiring connections.
2.7  Tighten all screws including the earth connections.
2.8  Switch on supply and check fan function.

CEILING JOIST MUST
BE ABLE TO
SUPPORT A
MINIMUM OF 15kg
THE SURFACE MUST
BE HORIZONTAL

RUBBER ROLLER

UPPER CANOPY

SCREWS

DOWN ROD

SAFETY

WIRE

J-HOOK

(SHOWN BROKEN)

Fig. A

FAN BLADE

FAN BLADE

MOUNTING SCREWS

SPRING WASHERS

FAN BLADE 

MOUNTING GASKET

FAN MOTOR BODY

Fig. B

Содержание ECOFAN P140

Страница 1: ...MARK ECOFAN P140 06 60 550_R02 Technical manual Technisch boek EN NL...

Страница 2: ...request The information in this document is subject to change without notice The most recent version of this manual is always available at www markclimate com downloads General warnings Installation...

Страница 3: ...a hanging weight of 15kg minimum Fig A 2 3 Fit the three blades to the fan body Fig B 2 4 Hang the fan on the hook with the safety wire then hook up the fan on the black rubber roller making sure that...

Страница 4: ...OWNWARD AIRFLOW LF LR N L N 1 PHASE SUPPLY 220 240 V 50 Hz CEILING FAN REVERSE ROTATION RUBBER ROLLER LF LR N L N 1 PHASE SUPPLY 220 240 V 50 Hz CEILING FAN LF LR N L N 1 PHASE SUPPLY 220 240 V 50 Hz...

Страница 5: ...wire 3 10 Replace the upper and lower downrod securing bolts and split pins 3 11 The feed wires will need to be cut and stripped to suit the shorter rod and then re connected to the lower terminal blo...

Страница 6: ...aanvraag leverbaar De informatie in dit document kan zonder voorafgaande kennisgeving worden gewijzigd De meest recente versie van deze handleiding is altijd beschikbaar op www mark nl downloads Algem...

Страница 7: ...g kan dragen Fig A 2 3 Plaats de drie bladen op het ventilatorhuis Fig B 2 4 Hang de ventilator aan de haak met het veiligheidsdraad en sluit vervolgens de ventilator op de zwarte rubberen rol aan en...

Страница 8: ...STE LUCHTSTROOM LF LR N L N 1 FASE VOEDING 220 240 V 50 Hz PLAFONDVENT OMGEKEERDE ROTATIE RUBBEREN ROLLER LF LR N L N 1 FASE VOEDING 220 240 V 50 Hz PLAFONDVENT LF LR N L N 1 FASE VOEDING 220 240 V 50...

Страница 9: ...tangbevestigingsbouten en splitpennen 3 11 De voedingsdraden moeten worden gesneden en gestript om te passen bij de kortere stang en vervolgens opnieuw worden aangesloten op het onderste aansluitblok...

Страница 10: ......

Страница 11: ......

Страница 12: ...belgium be MARK DEUTSCHLAND GmbH MAX PLANCK STRASSE 16 46446 EMMERICH AM RHEIN DEUTSCHLAND TELEFON 49 0 2822 97728 0 TELEFAX 49 0 2822 97728 10 info mark de www mark de MARK POLSKA Sp z o o UL JASNOG...

Отзывы: