MAREX 373 Aft Cabin Cruiser
Page
26 of
66
Test the gas system for leakages at a regular basis. Check all connections
for leakage by:
Testing and observing the bubble-leakage-tester in the compartment
on the bathing platform.
Manually test the system by adding soap and water to cranes and
valves. Make sure the cooker is closed and the bottle opening
–the
pressure reduction valve on the bottle- is open. Look for bubbles.
(D)
If you discover any leakage, close the system and immediately release the gas
bottle valve- the pressure reduction valve- and make sure an authorized person
repairs the system before you use it further.
The compartment where the gas bottle is kept is drained and the gas which is
heavier than air will be rained out under the bathing platform.
(D)
The pressure reduction valve must never be in contact with saltwater. If it gets in
contact with saltwater it will start to corrode. If any corrosion is seen it must be
changed before you use the gas system.
The pressure reduction valve must be controlled often and should be replaced
every year.
(D)
Must be changed if it gets in contact with salt
water because it will corrode.
Test button for leakage. Open the gas tank
valve and push the red button. If you can see
bubbles the system has a leakage between the
bottle and the cooker. Close the valves,
remove the bottle and call for assistance.
Disconnect the pressure reduction valve
when not in use.