Revision 1.2 

 

Page 3 

the shortest or lowest cost NMEA 2000

®

 drop cable. In fact, you can hook the TLA100 directly 

to a tee attached to the NMEA 2000

®

 trunk so you don’t have to purchase any drop cable. The 

actual mounting of the TLA100 is not critical and the unit can be mounted in any orientation. 
The TLA100, NMEA 2000

®

 connector, and cable are all waterproof (rated IP67 – protected 

against temporary immersion in water) so you can mount the unit virtually anywhere. Once you 
have located a suitable mounting location, you can secure the TLA100 by placing wire ties with 
screw eyes on the attached cables next to the TLA100. 

 

Figure 1– Mounting Location When Used with Analog Gauge 

 

2.2.2  Mounting Location When Used Without Analog Gauge(s) 

The TLA100 has two primary connections: 1) the NMEA 2000

®

 network connection, and 2) the 

resistive tank sender connection. Therefore, the TLA100 should be located between the NMEA 
2000

®

 trunk line and the resistive tank sender. The reason for choosing this location is 

because you will be connecting some of the wires within the TLA100’s permanently attached 
gray cable to the tank sender. Maretron recommends placing the TLA100 within 15 feet of the 
tank sender so the gray cable can be directly attached to the sender without any splices (see 
Figure 2). You may also consider placing the TLA100 as close as possible to the NMEA 2000

®

 

trunk line so you can purchase the shortest or lowest cost NMEA 2000

®

 drop cable. In fact, 

you can hook the TLA100 directly to a tee attached to the NMEA 2000

®

 trunk so you don’t 

have to purchase any drop cable. The actual mounting of the TLA100 is not critical and the unit 
can be mounted in any orientation. The TLA100, NMEA 2000

®

 connector, and cable are all 

waterproof (rated IP67 – protected against temporary immersion in water) so you can mount 
the unit virtually anywhere. Once you have located a suitable mounting location, you can 
secure the TLA100 by placing wire ties with screw eyes on the attached cables near the 
TLA100. 
 

www.busse-yachtshop.de  |  [email protected]

Содержание TLA100

Страница 1: ...l Adapter User s Manual Revision 1 2 Copyright 2006 Maretron LLC All Rights Reserved Maretron LLC 9034 N 23rd Ave 13 Phoenix AZ 85021 7850 http www maretron com Maretron Manual Part M000901 www busse...

Страница 2: ...ser s Manual Page ii Revision 1 2 Revision History Revision Description 1 0 Original document 1 1 Minor Updates 1 2 Corrected default values of transmitted PGN s www busse yachtshop de info busse yach...

Страница 3: ...Attached Gray Cable to Tank Sender 5 2 3 2 Connecting to NMEA 2000 Interface 6 3 Configuring the TLA100 6 3 1 Configuring Tank Type 7 3 2 Configuring Tank Number 7 3 3 Configuring Operating Mode 7 3 3...

Страница 4: ...When Used Without Analog Gauge 4 Figure 3 TLA100 Connections 4 Figure 4 NMEA 2000 Connector Face Views 6 Figure 5 Troubleshooting Guide 10 List of Tables Table 1 TLA100 Gauge Connections 5 Table 2 TLA...

Страница 5: ...joy the advantages of digitally networked information The Maretron TLA100 is designed to operate within the harsh demands of the marine environment However no piece of marine electronic equipment can...

Страница 6: ...e TLA100 can be used together with an analog gauge s referred to as NMEA 2000 Analog Gauge Mode or it can be used standalone to power and sense the resistive sender without an analog gauge s referred...

Страница 7: ...k line and the resistive tank sender The reason for choosing this location is because you will be connecting some of the wires within the TLA100 s permanently attached gray cable to the tank sender Ma...

Страница 8: ...d 2 the NMEA 2000 connection Refer to Section 2 3 1 for making the gauge or tank sender connection and Section 2 3 2 for making NMEA 2000 connection Caution Connect the TLA100 s permanently attached g...

Страница 9: ...symbol or a G for ground and the sensor connection is generally marked with an S for sensor or G for gauge You might have to refer to the gauge documentation or schematic to determine the exact funct...

Страница 10: ...is connected or disconnected Please follow recommended practices for installing NMEA 2000 network products Figure 4 NMEA 2000 Connector Face Views 3 Configuring the TLA100 The TLA100 has several confi...

Страница 11: ...of two modes 1 NMEA 2000 Mode or 2 NMEA 2000 Analog Gauge Mode You configure or place the TLA100 into NMEA 2000 Mode when you are connecting the TLA100 directly to the resistive tank sender see Figur...

Страница 12: ...terminal and the sensor terminal found on the back of the gauge Before making the measurement disconnect the power ground and sensor wires from the gauge Then measure and record the resistance betwee...

Страница 13: ...standard resistive tank sender is being used 2 A standard resistive tank sender is used but maximum accuracy is desired 3 The tank shape is irregular or non rectangular Regardless of the reason for c...

Страница 14: ...th the analog gauge and the resistive tank senders Although the TLA100 is a precision instrument it is only as good as the resistive sender which may not be as accurate as you like Avoid low cost resi...

Страница 15: ...an be Used With or Without Analog Gauges Certifications Parameter Comment NMEA 2000 Level B Maritime Navigation and Radiocommunication Equipment Systems Tested to IEC 60945 FCC and CE Mark Electromagn...

Страница 16: ...ist 4 times 7days 40 C 95 RH after 2 hour Salt Spray Per IEC 60945 8 12 Electromagnet Emission Conducted and Radiated Emission per IEC 60945 9 Electromagnetic Immunity Conducted Radiated Supply and ES...

Страница 17: ...IDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL MARETRON S AGGREGATE LIA...

Страница 18: ...TLA100 User s Manual Page 14 Revision 1 2 This page intentionally left blank www busse yachtshop de info busse yachtshop de...

Страница 19: ...ith a default value of zero 2 Fluid Type This field identifies the type of fluid contained within the tank Currently the defined fluid types are fuel fresh water wastewater live well oil and black wat...

Отзывы: