3.5  Standard Sender Selection or Custom Calibration 

The TLA100 is capable of accepting standard resistive values (see Section 3.5.1) or it can be 
calibrated for any resistance range between 0 and 300 or 300 and 0 ohms using the custom 
calibration procedure (see Section 3.5.2). In addition, the TLA100 can be calibrated for non-
rectangular tank shapes for any resistive tank sender having resistance values from 0 to 300 
ohms (see Section 3.5.2).  
 

3.5.1 Standard 

Sender 

Selection 

The TLA100 can be used with standard resistive tank senders such as the American Standard 
(240-30 ohms) or the European Standard (10-180 ohms). You can select which type of sender 
is attached to the TLA100 using a display product such as the Maretron DSM200. Refer to the 
user’s manual for configuring the TLA100 as the manual provides detailed instruction on 
configuration procedures. 
 

3.5.2 Custom 

Calibration 

The TLA100 can be custom calibrated for one of several reasons: 
 

1.  A non-standard resistive tank sender is being used, 
2.  A standard resistive tank sender is used, but maximum accuracy is desired, 
3.  The tank shape is irregular or non-rectangular. 

 
Regardless of the reason for custom calibrating the TLA100, you can calibrate the TLA100 
using a display product such as the Maretron DSM200. Refer to the user’s manual of the 
particular product that will be used for configuring the TLA100 as these manuals provide 
detailed instruction on configuration procedures. 
 

4 Maintenance 

Regular maintenance is not required, however, an occasional inspection will ensure continued 
proper operation of the Maretron TLA100. Perform the following tasks periodically: 

 

  Ensure that the unit is mounted securely and cannot be moved relative to the mounting 

surface.  If the unit is loose, tighten the screws holding the cable ties. 

  Check the security of the cables connected to the NMEA 2000

®

 interface and the 

connections to the gauge or sender and tighten if necessary. 

 

5 Troubleshooting 

If you notice unexpected operation of the Maretron TLA100, follow the troubleshooting 
procedures in this section to remedy simple problems. 
 
 
 
 
 
 

www.busse-yachtshop.de  |  [email protected]

Содержание TLA100

Страница 1: ...l Adapter User s Manual Revision 1 2 Copyright 2006 Maretron LLC All Rights Reserved Maretron LLC 9034 N 23rd Ave 13 Phoenix AZ 85021 7850 http www maretron com Maretron Manual Part M000901 www busse...

Страница 2: ...ser s Manual Page ii Revision 1 2 Revision History Revision Description 1 0 Original document 1 1 Minor Updates 1 2 Corrected default values of transmitted PGN s www busse yachtshop de info busse yach...

Страница 3: ...Attached Gray Cable to Tank Sender 5 2 3 2 Connecting to NMEA 2000 Interface 6 3 Configuring the TLA100 6 3 1 Configuring Tank Type 7 3 2 Configuring Tank Number 7 3 3 Configuring Operating Mode 7 3 3...

Страница 4: ...When Used Without Analog Gauge 4 Figure 3 TLA100 Connections 4 Figure 4 NMEA 2000 Connector Face Views 6 Figure 5 Troubleshooting Guide 10 List of Tables Table 1 TLA100 Gauge Connections 5 Table 2 TLA...

Страница 5: ...joy the advantages of digitally networked information The Maretron TLA100 is designed to operate within the harsh demands of the marine environment However no piece of marine electronic equipment can...

Страница 6: ...e TLA100 can be used together with an analog gauge s referred to as NMEA 2000 Analog Gauge Mode or it can be used standalone to power and sense the resistive sender without an analog gauge s referred...

Страница 7: ...k line and the resistive tank sender The reason for choosing this location is because you will be connecting some of the wires within the TLA100 s permanently attached gray cable to the tank sender Ma...

Страница 8: ...d 2 the NMEA 2000 connection Refer to Section 2 3 1 for making the gauge or tank sender connection and Section 2 3 2 for making NMEA 2000 connection Caution Connect the TLA100 s permanently attached g...

Страница 9: ...symbol or a G for ground and the sensor connection is generally marked with an S for sensor or G for gauge You might have to refer to the gauge documentation or schematic to determine the exact funct...

Страница 10: ...is connected or disconnected Please follow recommended practices for installing NMEA 2000 network products Figure 4 NMEA 2000 Connector Face Views 3 Configuring the TLA100 The TLA100 has several confi...

Страница 11: ...of two modes 1 NMEA 2000 Mode or 2 NMEA 2000 Analog Gauge Mode You configure or place the TLA100 into NMEA 2000 Mode when you are connecting the TLA100 directly to the resistive tank sender see Figur...

Страница 12: ...terminal and the sensor terminal found on the back of the gauge Before making the measurement disconnect the power ground and sensor wires from the gauge Then measure and record the resistance betwee...

Страница 13: ...standard resistive tank sender is being used 2 A standard resistive tank sender is used but maximum accuracy is desired 3 The tank shape is irregular or non rectangular Regardless of the reason for c...

Страница 14: ...th the analog gauge and the resistive tank senders Although the TLA100 is a precision instrument it is only as good as the resistive sender which may not be as accurate as you like Avoid low cost resi...

Страница 15: ...an be Used With or Without Analog Gauges Certifications Parameter Comment NMEA 2000 Level B Maritime Navigation and Radiocommunication Equipment Systems Tested to IEC 60945 FCC and CE Mark Electromagn...

Страница 16: ...ist 4 times 7days 40 C 95 RH after 2 hour Salt Spray Per IEC 60945 8 12 Electromagnet Emission Conducted and Radiated Emission per IEC 60945 9 Electromagnetic Immunity Conducted Radiated Supply and ES...

Страница 17: ...IDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL MARETRON S AGGREGATE LIA...

Страница 18: ...TLA100 User s Manual Page 14 Revision 1 2 This page intentionally left blank www busse yachtshop de info busse yachtshop de...

Страница 19: ...ith a default value of zero 2 Fluid Type This field identifies the type of fluid contained within the tank Currently the defined fluid types are fuel fresh water wastewater live well oil and black wat...

Отзывы: