Revision 1.0
Page 15
®
®
Environmental
Parameter
Value
IEC 60954 Classification
Exposed
Degree of Protection
IP64
Operating Temperature
-25°C to 55°C
Storage Temperature
-40°C to 70°C
Relative Humidity
93%RH @40° per IEC60945-8.2
Vibration
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8?
Solar Radiation
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist)
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission
Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity
Conducted, Radiated, Supply, and ESD
per IEC 60945-10
Safety Precautions
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
9 Technical Support
If you require technical support for Maretron products, you can reach us in any of the following
ways:
Telephone:
1-866-550-9100
Fax:
1-602-861-1777
E-mail:
World Wide Web:
http://www.maretron.com
Mail:
Maretron,
LLC
Attn: Technical Support
9014 N. 23
rd
Ave Suite 10
Phoenix, AZ 85021 USA