background image

TANKOPTIX FLEX - REV 1.2 
 

Weld Collar (OPTIONAL)

 

Installation of a weld collar is only required if the tank does not have an existing port that can 
be utilized. 

 

Installation 

1.

 

Cut a hole in top of tank to accommodate weld collar.  Avoid all internal baffles, piping, 
etc. Center the hole in the compartment to be measured both across the width and 
length of tank.  
 

2.

 

Place weld collar into tank approximately half way and apply a single tack weld to hold 
in place. 
 

3.

 

Adjust weld collar to ensure it is level parallel and perpendicular to tank’s horizontal 
centerline. 
 

4.

 

Once the weld collar has been leveled, weld into place. 
 

 

5.

 

Ensure the collar gasket is in place.  
 

6.

 

Insert sensor/probe assembly into weld collar and securely fasten into weld collar with 
supplied fasteners. 

 

Wiring

 

Once all of the equipment has been mounted, begin connecting all of the devices with the 
supplied quick connect cables.  Be sure to have all wiring fully secured before powering the 
system. All provided cabling and connectors should be clearly marked. - SEE PAGE 4.  

 

REMEMBER: 

 

Secure ALL wiring!  Run cables with a drip loop, and whenever possible utilize any 
existing wiring harnesses or raceways. 

 

DO NOT kink or bend any cabling. 

 

Bundle any excess cabling with wire ties.  

 

Tighten all quick connects! 

 

 

Содержание TankOptix FLEX

Страница 1: ...REV 1 2 FLEX MANUAL INSTALLATION GUIDE ...

Страница 2: ...rface Reading 3 Recommended Placement 3 Control Panel MFS200 D 4 5 Quick Connects 4 Recommended Placement 5 Sensor MFS2 D 5 Handling 5 Probe Assembly 5 INSTALLATION Mounting Equipment 6 7 Sensor 6 Panel Display 6 Antenna Placement 6 Weld Collar OPTIONAL 7 Wiring 7 8 Powering System 8 TankOptix Cloud 8 Maintenance 9 Support 12 ...

Страница 3: ...o the cloud Additional presses will cycle through the connected sensors if multiple sensors are connected and or extend the system power on time by 30 seconds 24 7 Mode If multiple sensors are connected pressing the refresh button will cycle through the connected sensors If TankOptix Cloud reporting is enabled pressing and holding the refresh button for 1 sec will register the input and report the...

Страница 4: ...The interface reading is from the bottom of the tank to the first level The level reading is from the bottom of the tank to the to the top level or the tank s total volume Recommended Placement The Display is a NEMA 4 IP66 weatherproof polycarbonate enclosure Please contact us for any custom bracket or mounting requirements Common placement in a truck installation is the driver side floorboard If ...

Страница 5: ...o sensors Follow the diagram included with Y quick connect splitter for installation 4 Sensor Configuration If the system is utilizing 4 sensors please utilize the DISPLAY connection of the panel for sensor 4 A local display is not possible when utilizing 4 sensors TankOptix Cloud reporting is required in this application Making the Connection 1 Ensure connection of the device with the proper cabl...

Страница 6: ...n the application Before installation of the sensor ensure the probe is properly attached If utilizing and existing tank port the sensor will be supplied with an adapter flange This adapter should already be attached to the sensor DO NOT REMOVE IT If you are supplied with a rod probe the sensor may have a re enforcement collar already attached DO NOT REMOVE IT In the event the sensor is delivered ...

Страница 7: ...th and length to minimize measurement errors due to leveling DO NOT mount probe in manways or adjacent to inlets outlets drains or other obstacles within the tank Panel Display Please reference Recommended Placement for each component of the system Improper placement of the equipment may result in damage to the system Antenna Placement If the control panel is configured for TankOptix Cloud reporti...

Страница 8: ...o tank s horizontal centerline 4 Once the weld collar has been leveled weld into place 5 Ensure the collar gasket is in place 6 Insert sensor probe assembly into weld collar and securely fasten into weld collar with supplied fasteners Wiring Once all of the equipment has been mounted begin connecting all of the devices with the supplied quick connect cables Be sure to have all wiring fully secured...

Страница 9: ...er or Duracell Ultimate Lithium Batteries Power Adapter 120V If powering the device through a standard outlet simply connect the power adapter to the power connection on the control panel and plug into any standard 120v outlet Power Leads 12V For truck installations or solar panel connections a power lead quick connect will be provided For truck installation please follow directions below Before C...

Страница 10: ...GPS TankOptix Remote Service Support Maintenance The TankOptix sensor has no moving parts never needs calibration To ensure long term operation of your equipment scheduled maintenance is advised WHEN MAINTENANCE Preforming heavy duty mechanical installation or maintenance on tank Remove sensor probe assembly from the tank During cleaning of tank or every 6 months Remove sensor probe assembly from ...

Страница 11: ...ORT Monday Friday 8 30AM 5 00PM EST 1 800 919 2652 support mfsltd com When calling please reference TankOptix Support TankOptix Copyright 2016 The TankOptix name logos and related marks are trademarks of Marengo Fabricated Steel LTD ...

Отзывы: