background image

11

Mareli Systems

The main frame shows: 

time and date, chrono activation, combustion 

power and recipe, functioning state, error code, 

main temperature, main thermostat, 

summer/winter mode.

Button 

Function 

P1 

P2 

P3 

P4 

P5

 

P6

 

Exit Menu/Submenu;
Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono;
Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data;
Enter in Visualizations Menu, Increase
Activation chrono time band
Enter in Visualizations Menu, Decrease

Led

 

Function 

D1 

D9 

D2 

D10 

D3 

D11 

D5 

D12 

Auger ON

V2:

 Pump 1 ON

R: 

Igniter ON 

Aux2: 

Pump 2 ON

 

External Chrono reached

Lack of pellet

Local Room Thermostat reached

Sanitary water demand

Er01 

- Security Error High Voltage 1. It may also intervene with the system off;

Er02 

- Security Error High Voltage 2. It can only intervene if the Combustion fan is active;

Er03 

- Extinguishing for low exhaust temperature or missing light in the brazier;

Er04 

- Extinguishing for water over temperature;

Er05 

- Extinguishing due to high exhaust temperature;

Er06 

- Pellet Thermostat open (flame return from the brazier);

Er07 

- Encoder Error. The error may occur due to lack signal from Encoder;

Er08 

- Encoder Error. The error can occur due to problems of adjustment of the number of revolutions;

Er09 

- Water pressure low;

Er10 

- Water pressure high;

Er11 

- Clock Error. The error occurs due to problems with the internal clock;

Er12 

- Extinguishing for ignition failure;

Er15 

- Extinguishing due to power failure for more than 50 minutes;

Er16 

- RS485 communication error (Display);

Er17 

- Adjusting the Air Flow Failed;

Er18 

- No more Pellet in the bunker;

Er23 

- Boiler probe or Back boiler probe or probe Buffer open;

Er25 

- Engine cleaning brazier broken;

Er26 

- Engine cleaning broken;

Er27 

- Engine cleaning 2 broken;

Er34 

- Depression below the minimum threshold;

Er35 

- Depression above the maximum threshold;

Er39 

- Sensor Flowmeter broken;

Er41 

- Minimum air flow in Check Up is not reached;

Er42 

- Maximum air flow exceeded;

Er44 

- Open door error;

Er47 

- Error Encoder Auger: missing signal Encoder;

Er48 

- Error Encoder Auger: Auger regulation speed not achieved;

Er52 

- Error Module I/O I2C; 

Er57 

- Test ’Forced Draught High’ in Check Up fail ;

Service 

- Service error. It notifies that the planned hours of functioning is reached. It is necessary to call for service.

ALARMS

CONTROL PANEL: USE AND FUNCTIONS

Содержание SMB 50

Страница 1: ...SMB 50 Pellet burner Assembly and exploitation manual Mareli Systems...

Страница 2: ...y an adult who is familiar with the operating conditions Introduction of inflammable liquids in room with a working burner is strictly prohibited Children should not be left unattended in the room whe...

Страница 3: ...lied to the flexible tube The flexible tube is made of special heat resistant material which in the case of combustion does not emit toxic substances and connects the auger and pellet burner End view...

Страница 4: ...urely attach a pellet burner to the door through M8 screws which are screwed where the thread is made on the door itself which holds the burner to the door Explanation It must be checked whether seali...

Страница 5: ...or about 3 hours for the chimney to be warmed up and measure the draught Install addition al chimney fan controlled by the control unit of the burner if necessary The heat exchange surface is made of...

Страница 6: ...omical and efficient operation of the boiler burner system in the installation Why is regular maintenance important Heating systems should be maintained on a regular basis for the following reasons To...

Страница 7: ...aintenance The use of special protec tive equipment safety goggles tightly fitted is recommended CAUTION Periodic cleaning as well as supervision of the burner will prevent any incidents caused by fau...

Страница 8: ...from the burner and collect the pellets passed from the conveyor into a bag for 10 min Weigh the pellets passed and multiply by the factor 0 03 The calculated value is the power in KW h Example If th...

Страница 9: ...ner settings to use exhaust gas analyser IMPORTANT Default values of the parameters should not be taken for granted The settings must be adjusted individually according to REQUIRED POWER TILT OF THE S...

Страница 10: ...user you may only make repairs which involve just a simple replacement of the grate In case of first commissioning of the boiler condensation of water vapour on the heating surfaces of the heat excha...

Страница 11: ...stat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of rev...

Страница 12: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Страница 13: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Страница 14: ...14 Mareli Systems WIRING DIAGRAM...

Страница 15: ...15 Mareli Systems...

Страница 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: