46
Command mode
1. Command Format A
Host
Command
<CR>< LF>
Slave
Command
<CR>< LF>
MZ
Zero
CZ
Zero compensation On/OFF
MT
Tare
CT
Clear TARE value
MG Gross Weight
MN
Net weight
AT
Accu. Current net weight and times plus 1.
ST
Deduct times of last accu. Value minus 1
DT
Clear accu. Value and times
BB
Start batching (one time)
HB
Load stop
BD
Start unload
SC
Transmit continuous
SA
Auto transmit
SM
Manual transmit
SO
Command mode
%
Stop continuous transmission and enter the command mode
2. Command Format B
Host
Command
<CR>< LF>
Slave
Data
<CR>< LF>
RW Read current weight
RT Read TARE
RG
Read Gross Weight
RN Read Net weight
RB
Read current display of wt (simple)
RH Read Gross (simple)
RI
Read Net (simple)
RJ
Read comparison sit current display of weight (simple)
RK
Read comparison sit Gross (simple)
RL
Read comparison sit Net (simple)
RO
Read comparison situation (2)
RF
Read prior completed weight
RA Read accu. Value (incl. times)
Note
:
Prior command plus %
Read Weight Compared value: RS
□□
□□
: Setting items
FW
Read target item of unload value
S1
Read SP1
S2
Read SP2
S3
Read SP3
UD
Read Under
LO
Read LO
ZB
Read Zero Band
HI
Read HI
PR
Reading Peak value
OV
Read Over
Ex:
Command : RSFW
<
CR
><
LF
>
TD-100 reply : RSFW
□□□□□□
Finish 6 bytes