71
Item
Function
Setting value
Default
Parameter
Description
SQ- 01
Batching mode
1
Normal batch
1
2
Loss-in weight
3
Comparison mode
4
Normal batch (Built-in program)
5
Loss-in weight (Built-in program)
6
Hold mode (Built-in program)
SQ- 02 Batching start delay time
0.0 ~ 25.5
(sec)
The built-in auto-program starts the
batch comparison procedure after the
input of the batch start signal.
0.0
SQ- 03
SP1,SP2
Waiting time comparison
0.0 ~ 25.5
(sec)
No full flow comparison during this
function’s set time period. If the set
value is 0, indicates this function is not in
use.
0.0
SQ- 04
Batch finish output signal
delay time
0.0 ~ 25.5
(sec)
Output the batch finished signal after
this delay time.
0.5
SQ- 05
Batch finish Condition
0
Wait until the weight is stabilized
0
1
No need to wait until the weight has
stabilized
SQ- 06
Batch finish
Output signal time
0.0 ~ 25.5
(sec)
Batch finished output signal time.
If set to 0, the output signal will be off
until the next batch start.
1.0
Batch finish signal
ON
SQ 04
OFF
SQ 06
Batch finish
SQ- 07
Number of Times the
supplementary loading
function operates
0 ~ 255
If the set value is 0, this function is not in
use.
0
SQ- 08
Supplementary loading
gate open time
0.0 ~ 25.5
(sec)
Must be coordinate with times of
supplementary loading, (SQ- 07)
0.1
SQ- 09
Supplementary loading
gate close time
0.0 ~ 25.5
(sec)
Must be coordinate with times of
supplementary loading, (SQ- 07)
1.0
Supplementary loading signal
SQ- 08 SQ- 08
ON SQ- 09
SQ- 09
OFF
SQ-
07 Times of “ON” of the supplementary loading