1900053
REV.5
Page 3
Figure 1: Machine User Interface
NOTE:
Because the boiler is electronically controlled no priming is necessary.
The element cannot switch on until a safe level of water is reached.
ECO Mode Opera tion:
All Ecoboilers use high grade insulation and it is applied to give a significant energy usage
improvement over a standard water boiler.
The 20 & 30L Ecoboiler variants also incoprate a
½ tank ‘ECO mode’ function.
To enable the ‘ECO Mode’ press the button located below the ‘Ready’ indicator so that the leaf
symbol illuminates green.
This mode saves energy by mimimising the energy wasted during machine down-time.
NOTE: The ECO mode is most effective in installations where the machine has a regular ‘off’
period.
To achieve the most benefit from the ener
gy saving ‘ECO Mode’ on your Ecoboiler unit, the
following method should be employed:
o
Towards the end of the boilers operating period for a given day, switch the machine to
ECO Mode. Whilst maintaing water at 96
o
C, the machine tank will slowly drop to half
full, where it will remain.
o
At the end of the machines operating p
eriod it should the be turned ‘off’.
o
During the ‘off’ period as there is less water in the tank there will be less energy lost to
the surrounding environment resulting in an energy saving.
To disable simply press the ‘ECO Mode’ button again so that the leaf symbol is not illuminated
TROUBLESHOOTING:
The Ready/Status light signals various errors or problems. A cycle of red flashes indicates an error.
The number of flashes in a cycle corresponds to the symptom in the table below:
Status/Dia gnostic light gui de:
No of
flashes
Symptom
Ac tion re quired
2
Water level below elements. Normal
when machine first fills.
Check water pressure , if this is OK then call
service agent.
3
Temperature sensor failure (o/c)
Call service agent
4
Water not heating
Call service agent
5
Temperature sensor failure (s/c)
Call service agent
Power
Button
Ready/Status
Indicator
Ecomode
Button
Содержание ECOBOILER T20-3