HAZARD IDENTIFICATIONS

Failure to comply with ANY WARNING listed below could result in death or serious injury.

 

This product is not for use in wet environments. Always use a Ground Fault Interrupter Circuit (GFIC) for 

all electrical power source connections. Use of this product in wet environments could create a shock or 

electrocution hazard.

 

Frozen moisture could cause restrictions and obstructions in pneumatic control lines. Any restriction or 

obstruction in the pneumatic control lines could prevent the proper activation and deactivation of the remote 

control system, resulting in the release of high speed abrasive and compressed air. In conditions where moisture 

may freeze in the control lines an antifreeze injection system approved for this application can be installed.

 

Do not cut, obstruct, restrict or pinch pneumatic control lines. Doing so could prevent the proper activation and 

deactivation of the remote control system, resulting in the release of high speed abrasive and compressed air.

 

Use of Marco remote control switches with other manufacturer’s remote control systems could cause unintended 

activation of remote control systems resulting in the release of high speed abrasive and compressed air. Only 

Marco remote control switches should be used with Marco remote control systems.

 

Always be certain to have secure footing when abrasive blasting. There is a recoil hazard when abrasive blasting 

starts that may cause user to fall and misdirect the abrasive stream at operator or bystander.

 

Never use an abrasive blasting pot or attachments as a climbing device. The person could slip and fall. The 

abrasive blasting pot could become unstable and tip over.

 

For equipment manufactured by entities other than Marco, you must consult the Original Equipment Manufacturer 

operator’s manuals, information, training, instructions and warnings, for the proper and intended use of all 

equipment.

 

Flammable fumes, such as solvent and paint fumes in the work area can present an ignition or explosion hazard 

if allowed to collect in adequate concentrations. To reduce conditions that could result in a fire or an explosion, 

provide adequate ventilation, eliminate all ignition or spark sources, keep the work area free of debris, store 

solvents and solvent contaminated rags in approved containers, follow proper grounding procedures, do not 

plug/unplug power cord or turn on/off power switches when flammable fumes are present, keep a working fire 

extinguisher or provide another fire suppression system in the work area. Cease all operations and correct 

condition if a spark or ignition source is identified during operation.

 

Always depressurize the entire system, disconnect all power sources and lockout/tagout all components before 

any maintenance or troubleshooting is attempted. Failure to comply with the above warning could cause electrical 

shock and inadvertent activation of equipment resulting in death or serious injury.

 

Moving parts can present an area where crushing, pinching, entanglement or amputation may occur. Do not 

place body parts or foreign objects in any area where there are moving parts.

 

Surfaces of heated supply tanks, drums and/or lines as well as the adjoining plumbing may become hot during 

normal use. Do not touch these heated surfaces without proper protection. Deactivate and allow sufficient time for 

all surfaces to cool before attempting any maintenance.

 

High-pressure fluid from gun, hose leaks, or ruptured components can pierce skin and can cause a serious injury 

that may result in amputation. Do not point gun or spray tip at anyone or at any part of the body. Keep clear 

of any leaks or ruptures. Depressurize the entire system before attempting cleaning, inspecting, or servicing 

equipment.

 

Exposure to toxic fluids or fumes may occur during the normal operation of this system.  Before attempting to 

fill, use, or service this system, read SDS’s to know the specific hazards of the fluids you are using. Always use 

proper Personal Protective Equipment when attempting to fill, use, or service this system.

 

The use of this product for any purpose other than originally intended or altered from its original design is 

prohibited.

 

Never hang objects from the abrasive blasting pot handle. Doing so may cause the abrasive blasting pot to 

become unstable and tip over. 

Содержание Blastmaster 950 CFM

Страница 1: ...loyer of the user and or assistants must provide adequate and necessary training to ensure proper operation and compliance with all safety procedures pertaining to this equipment If Operator s Manuals...

Страница 2: ...equipment As the largest provider of surface preparation and protective coatings equipment in the world our inventory levels and product availability are unmatched Logistics Services Marco s in house...

Страница 3: ...ist 8 Operating Instructions 9 Description 9 Operating Instructions 11 Loading the Blastmaster 950 CFM Air Dryer 15 Specifications 16 Maintenance 17 Remove Install Inspection Door 17 Remove Install Tr...

Страница 4: ...afety Standards Inspect all equipment for wear or damage before and after each use Failure to use Original Equipment Manufacturer repair parts and failure to immediately replace worn or damaged compon...

Страница 5: ...ct in adequate concentrations To reduce conditions that could result in a fire or an explosion provide adequate ventilation eliminate all ignition or spark sources keep the work area free of debris st...

Страница 6: ...volume of air exists and petcock is unable to be left open at all times petcock should be opened frequently to release water To reduce abrasive intrusion in the air supply hose depressurize the abrasi...

Страница 7: ...3 Air cfm Abrasive lbs hr Compressor Horsepower No 4 1 4 47 268 11 54 312 12 61 354 14 68 408 16 74 448 17 81 494 18 98 608 22 110 681 25 Air cfm Abrasive lbs hr Compressor Horsepower No 5 5 16 77 468...

Страница 8: ...Blastmaster 950 CFM Air Dryer 7 THE BIG PICTURE 3 5 7 4 4 3 2 1 8 9 17 14 16 15 13 19 18 10 20 23 21 4 24 27 26 25 22 28 5 3 6 11 12...

Страница 9: ...lasting Hose 19 and Air Hose 4 connection points Aftercooler and Moisture Separator Ensure Aftercooler 28 is positioned on stable ground Keep petcock drain of Moisture Separator 23 slightly open durin...

Страница 10: ...Pneumatic Air supply of 50 cfm 85 psi The following may cause safety hazards or reduced performance Improper installation and or maintenance of components Incorrect disassembly and or incorrect reass...

Страница 11: ...Blastmaster 950 CFM Air Dryer 10 OPERATING INSTRUCTIONS Pneumatic Electric...

Страница 12: ...l Slowly turn on air supply to connected device s If leaks are found turn off air supply open Drain 6 allow air pressure to completely release and address leaks as needed During use Every hour observe...

Страница 13: ...Blastmaster 950 CFM Air Dryer 12 OPERATING INSTRUCTIONS 10 11 6 1 2 3 4 5 15 12 13 14 16 7 8 9...

Страница 14: ...of liquids If no liquid is being released adjust as needed Observe desiccant levels through Sight Glass 8 After use Turn off air supply to connected device s Turn off compressed air supply Turn off El...

Страница 15: ...Blastmaster 950 CFM Air Dryer 14 OPERATING INSTRUCTIONS 1 12 13 2 3 4 5 6 7 8 9 10 11...

Страница 16: ...replace worn or damaged components could void warranties and cause malfunctions Failure to comply with the above warning could result in death or serious injury Loading the Blastmaster 950 CFM Air Dry...

Страница 17: ...brication SAE 10 oil or Air Tool Anti freeze Lubricant Tank Outlet Ports 1 3 2 1 Tank Inlet Ports 1 3 SPECIFICATIONS Empty Weight 1200 lbs Overall Dimensions A 91 B 35 C 72 A C B Pneumatic model shown...

Страница 18: ...ry W 562 Inspect all equipment for wear or damage before and after each use Failure to use Original Equipment Manufacturer repair parts and failure to immediately replace worn or damaged components co...

Страница 19: ...d void warranties and cause malfunctions Failure to comply with the above warning could result in death or serious injury 1 Depressurize entire system 2 Disconnect Hose 1 Full Port Ball Valve 2 Hex Ni...

Страница 20: ...emove Filter Regulator Lubricator Assembly 2 6 Install parts in reverse order 1 3 3 4 4 1 2 3 7 8 9 5 6 Inspect all equipment for wear or damage before and after each use Failure to use Original Equip...

Страница 21: ...emove Air Filter Regulator Lubricator Assembly See Remove Install Air Filter Regulator Lubricator Assembly Note Approximate weight of Aftercooler Assembly is 200 pounds Use suitable lifting devices to...

Страница 22: ...ly Electric Only 1 Depressurize entire system 2 Remove Transfer Hose Assembly See Remove Install Transfer Hose Assembly 3 Remove Intake Filter Assembly See Remove Install Intake Filter Assembly 4 Remo...

Страница 23: ...from Coupling 2 4 Remove Elbow 4 and Hex Nipple 5 from Motor 7 5 Install parts in reverse order 1 2 Always depressurize the entire system disconnect all power sources and lockout tagout all components...

Страница 24: ...arate Hose 5 from Hose Stems 1 Discard hose 3 Install parts in reverse order using the following special instructions Note Periodic bolt re tightening is necessary due to cold flow present in all rubb...

Страница 25: ...pect condition of motor Fill the lubricator reservoir with SAE 10 oil or Air Tool Anti freeze Lubricant Adjust the lubricator to feed one drop of oil for every 50 75 CFM of air passing through the air...

Страница 26: ...Blastmaster 950 CFM Air Dryer 2 Open Ball Valves 1 2 3 to drain any excess moisture 3 Close Ball Valves 1 2 3 4 Disconnect air hose from Inlet 4 and Outlet 5 5 Install a cover on Inlet 4 and Outlet 5...

Страница 27: ...residue 9 Place Spherical Tower Packing back in unit for storage See Load Tank 10 Store with Inspection Door removed Always depressurize the entire system disconnect all power sources and lockout tago...

Страница 28: ...nt Muffler obstructed or fouled Check air supply to air motor confirm supply air is on and set to 85 psi Clear any obstructions from fan blades Inspect fan blades for damage Replace damaged components...

Страница 29: ...ly Improper electric supply Improper connection Obstruction Damaged components Check the connections to power supply and confirm solid contact Clear any obstructions from fan blades Inspect fan blades...

Страница 30: ...Blastmaster 950 CFM Air Dryer 29 DATE TYPE OF SERVICE PART NUMBER MAINTENANCE NOTES...

Страница 31: ...OR OTHERS WITHOUT SELLER S PRIOR WRITTEN CONSENT IF SUCH NOTICE IS TIMELY GIVEN SELLER WILL HAVE THE OPTION TO EITHER MODIFY THE PRODUCT OR COMPONENT PART THEREOF TO CORRECT THE DEFECT REPLACE THE PRO...

Страница 32: ...0 BLAST IT 800 252 7848 ph 563 324 2519 fax 563 324 6258 40 NATIONWIDE SHIPPING LOCATIONS Marco Regional Branch Offices and Shipping Locations Direct Shipping Locations CONTACT MARCO 800 BLAST IT 800...

Отзывы: