26
MAINTENANCE
Long-Term Storage Procedure
1) Depressurize Blastmaster
®
950 CFM Air Dryer.
2) Open Ball Valves (1,2,3) to drain any excess moisture.
3) Close Ball Valves (1,2,3).
4) Disconnect air hose from Inlet (4) and Outlet (5).
5) Remove Inspection Door (6). See Remove and Install Inspection Door.
6) Remove Desiccant Tablets. Observe levels through Site Glass (7), being careful not to
remove Spherical Tower Packing.
7) Remove and wash Spherical Tower Packing.
8) Clean inside of tank to reduce internal corrosion caused by moisture and desiccant
residue.
9) Place Spherical Tower Packing back in unit for storage. See Load Tank
.
10) Store with Inspection Door removed.
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
W-562
Inspect all equipment for
wear or damage before
and after each use.
Failure to use Original
Equipment Manufacturer
repair parts and failure to
immediately replace worn
or damaged components
could void warranties
and cause malfunctions.
Failure to comply with
the above warning could
result in death or serious
injury.
1
2
3
4
5
6
7
Содержание Blastmaster 950 CFM
Страница 11: ...Blastmaster 950 CFM Air Dryer 10 OPERATING INSTRUCTIONS Pneumatic Electric...
Страница 13: ...Blastmaster 950 CFM Air Dryer 12 OPERATING INSTRUCTIONS 10 11 6 1 2 3 4 5 15 12 13 14 16 7 8 9...
Страница 15: ...Blastmaster 950 CFM Air Dryer 14 OPERATING INSTRUCTIONS 1 12 13 2 3 4 5 6 7 8 9 10 11...
Страница 30: ...Blastmaster 950 CFM Air Dryer 29 DATE TYPE OF SERVICE PART NUMBER MAINTENANCE NOTES...