Marco 164 936 15-US - OCK8-E Скачать руководство пользователя страница 5

©                    S.p.A.

PRODUCT DESCRIPTION

TECHNICAL DETAILS

APPLICATIONS

FLUIDS ALLOWED / NOT ALLOWED

Ø

Ø

transfer of viscous liquids

Ø

circulation of viscous liquids

Ø

draining of engine sumps.

There are numerous fields of applications for the pump, however only exclusively with the 

allowed liquids mentioned:

Transfer of oils, antifreezing

Self-priming electric pump for the transfer of liquids of varied nature. The pumping elements 

are made up of bronze gears which can possibly even run dry for brief periods.

Tab.1 EN

CODE

TYPE

VOLT

50,8

2,6

OCK8-E

AW G

16

lb

IP 67 Protection

(*) Internal tube Ø 1/2 in, water at 25 °C / (**) Length up to 6.6 ft

A

164 936 15-US

12/24V

15

psi

4,9

gpm

FUSE

FLOW RATE (*)

WIRE SIZE (**)

PRESSURE

WEIGHT

5

Tab.2 EN

DIESEL FUEL (*)
OIL (max 120 °C - 248 °F)
WATER (max 85 °C - 185 °F)
PETROL (GASOLINE)

FLAMMABLE LIQUIDS with PM< 38 °C

LIQUIDS WITH VISCOSITY > 20 cSt

CORROSIVE CHEMICAL PRODUCTS

• •

SOLVENTS

D

A

M

A

G

E

T

O

S

E

A

LS

OK

NO

(*) Minimum flashpoint (PM): 38 °C - 100 °F

IN

JU

R

Y

T

O

P

E

R

S

O

N

N

E

L

LIQUIDS

DANGERS

WARRANTY EXPIRES IF MAX FLUID 

TEMPERATURE IS EXCEEDED

F

IR

E

/

E

X

P

LO

S

IO

N

M

O

T

O

R

O

V

E

R

H

E

A

T

IN

G

P

U

M

P

C

O

R

R

O

S

IO

N

Содержание 164 936 15-US - OCK8-E

Страница 1: ...164 936 15 US OCK8 E 12 24V 27 11 19 Rev 01 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS...

Страница 2: ...to move After choosing the direction pressing the ON OFF key will start the motor the LED indicating the direction will become solid and the FLOW LED will also light up indicating that the motor is r...

Страница 3: ...of the external control is toggled The external control needs a special cable and has to be requested when the pump order is placed otherwise it just keeps the pump always on The ON OFF and the CHANG...

Страница 4: ...rature threshold of 65 C 149 F is exceeded the motor will stop immediately and will not restart until it returns below 55 C 131 F The signal is a slowly blinking red LED If the supply voltage when the...

Страница 5: ...gears which can possibly even run dry for brief periods Tab 1 EN CODE TYPE VOLT 50 8 2 6 OCK8 E AWG 16 lb IP 67 Protection Internal tube 1 2 in water at 25 C Length up to 6 6 ft A 164 936 15 US 12 24...

Страница 6: ...shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended that the use of the pump be according to normative safety standards and also a...

Страница 7: ...dany possibleenvironmental dispersion In this case frequent cleaning and maintenance of the filter is advisable The standardfilter withstands a maximumpositive pressure of0 5 bar The electrical instal...

Страница 8: ...umphas run dry for too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the following re...

Страница 9: ...pose of this product by means of the specific refuse collection structures indicated by the government orthe local governing authorities The user is invited to effect a proper waste separation in orde...

Страница 10: ...S p A EXPLODED VIEW 10...

Страница 11: ...S p A DIMENSIONS 11...

Страница 12: ...S p A DIAGRAMS FLOW RATE DIAGRAM 0 1 2 3 0 0 14 5 29 0 43 5 58 0 72 5 psi gpm 0 5 10 15 0 0 14 5 29 0 43 5 58 0 72 5 psi A AMPERE DRAW DIAGRAM 12V 24V 12...

Страница 13: ...S p A WARNING HOT SURFACE 13...

Страница 14: ......

Страница 15: ...eclaration is valid for all products which are produced in accordance with the technical documentation which is a part of this declaration For verification of conformity with regard to the Electromagn...

Страница 16: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...

Отзывы: