Marco 164 936 15-US - OCK8-E Скачать руководство пользователя страница 2

©                    S.p.A.

FEATURES

2

·

The circuit lights up:

o

 The green and red LEDs slowly flash, while the circuit is performing 

the initial self-check and parameter reset.

o

If something fails, the pump does not come out of this condition and 

the red and green LEDs continue to blink indefinitely.

·

After self-check:

o

The "RUN" LED starts blinking: the pump is waiting for the direction 

to be  chosen.

o

By  pressing  the  “CHANGE  DIRECTION”  button,  the  pumping 

direction can be set and the relative LED will start to blink together 

with "RUN" LED.

o

If you do not press the “CHANGE DIRECTION” button when only 

the  "RUN"  LED  is  blinking,  but  instead  you  press  the  "ON/OFF" 

button, the pump will not start: the "FILL" and "DRAIN" LEDs will 

flash fast alternately to indicate "I do not know in which direction I 

have to move".

·

After choosing the direction, pressing the "ON / OFF" key will start the motor: 

the LED indicating the direction will become solid and the “FLOW” LED will 

also light up indicating that the motor is running.

·

The  motor  speed  setting  is  set  by  default  to  the  maximum  achievable:  if 

current limitation occurs, the “FLOW” LED starts to flash, indicating that the 

motor cannot maintain the revolutions due to excessive load.

·

It is possible to change the motor speed (in 100rpm steps) by pressing the 

“TURTLE” and “HARE” keys. The speed setting applies to both directions of 

rotation and remains stored in the memory until the pump is switched off.

·

To save the current direction and speed in permanent memory, to have them 

by  default  each  time  the  pump  is  switched  on,  press  and  hold  down  the 

“CHANGE DIRECTION” key for a long time, until the direction LED starts 

blinking. This operation with the pump switched off resets the direction to its 

default value, but does not edit the speed value.

Содержание 164 936 15-US - OCK8-E

Страница 1: ...164 936 15 US OCK8 E 12 24V 27 11 19 Rev 01 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS...

Страница 2: ...to move After choosing the direction pressing the ON OFF key will start the motor the LED indicating the direction will become solid and the FLOW LED will also light up indicating that the motor is r...

Страница 3: ...of the external control is toggled The external control needs a special cable and has to be requested when the pump order is placed otherwise it just keeps the pump always on The ON OFF and the CHANG...

Страница 4: ...rature threshold of 65 C 149 F is exceeded the motor will stop immediately and will not restart until it returns below 55 C 131 F The signal is a slowly blinking red LED If the supply voltage when the...

Страница 5: ...gears which can possibly even run dry for brief periods Tab 1 EN CODE TYPE VOLT 50 8 2 6 OCK8 E AWG 16 lb IP 67 Protection Internal tube 1 2 in water at 25 C Length up to 6 6 ft A 164 936 15 US 12 24...

Страница 6: ...shipment Upon receiving the packaging should be inspected for damages and the pump stored in a dry area It is recommended that the use of the pump be according to normative safety standards and also a...

Страница 7: ...dany possibleenvironmental dispersion In this case frequent cleaning and maintenance of the filter is advisable The standardfilter withstands a maximumpositive pressure of0 5 bar The electrical instal...

Страница 8: ...umphas run dry for too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the following re...

Страница 9: ...pose of this product by means of the specific refuse collection structures indicated by the government orthe local governing authorities The user is invited to effect a proper waste separation in orde...

Страница 10: ...S p A EXPLODED VIEW 10...

Страница 11: ...S p A DIMENSIONS 11...

Страница 12: ...S p A DIAGRAMS FLOW RATE DIAGRAM 0 1 2 3 0 0 14 5 29 0 43 5 58 0 72 5 psi gpm 0 5 10 15 0 0 14 5 29 0 43 5 58 0 72 5 psi A AMPERE DRAW DIAGRAM 12V 24V 12...

Страница 13: ...S p A WARNING HOT SURFACE 13...

Страница 14: ......

Страница 15: ...eclaration is valid for all products which are produced in accordance with the technical documentation which is a part of this declaration For verification of conformity with regard to the Electromagn...

Страница 16: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...

Отзывы: