ALARMS AND INDICATORS
Battery Backup: Slow beeping tone (approx. 0.25Hz)
Battery Low: Rapid beeping tone (approx. 1.00Hz)
Overload: Continuous tone
Front Panel Display
:
LED on standard runtime models & LED or LCD on extended runtime models
Display Parameters (LED): On Line (AC normal), On Battery (AC failure), AVR Boost, AVR Buck,
Battery Capacity/Level (%), Load Level (%), Overload
Display Parameters (LCD): Input voltage, Output voltage, Input Frequency, Output Frequency,
Load (%), Internal Temperature (°C)
Communication (std): RS-232 bi-directional communication port and solid state signaling
(optional): SNMP/WEB card or module for monitoring and control on network or internet
STANDARDS
Safety
:
EN50091-1-1
Emissions:
EN50091-2 class B
Immunity:
EN50091-2
Conformity:
UL 1778, cUL
107.1, 107.2
,
(120V models),
CE
(230V Models)
Transient Immunity (120V):
Per IEEE 62.41
(formerly IEEE 587)
Transient Immunity (230V)
:
Per IEEE C 61000-4-5 level 3
230V Rack-Mount Models (2U): TRMU-0600-02, TRMU-1000-02, TRMU-1500-02, TRMU-2000-02, TRMU-3000-02
ENVIRONMENTAL
Ambient temperature range:
+32 °F to +
95
°F
(+0 °C to +
35
°C)
(1000 ~ 2000VA extended run-time models)
+32 °F to +104°F (+0 °C to +40 °C) (All standard run-time models)
+32 °F to +77°F (+0 °C to +25 °C) (3000VA extended run-time models)
Optimum temperature range:
+59 °F to +77°F (+15 °C to +25 °C)
Storage temperature:
+5 °F to +122°F (-15 °C to +50 °C)
Cooling:
Forced air cooling
Humidity:
0-95%,
n
on-condensing
Elevation
:
10,000 feet max (operation), 45,000 feet (storage)
Audible noise:
< 4
0
db normal and battery mode (
6
00-1000 VA models)
<
4
5 db normal and battery mode (1500-3000 VA models)
29
MODEL & PART NUMBER DESIGNATION - Extended Run-Time Models
120V Tower Models: TTWE-1000-01, TTWE-1500-01, TTWE-2000-01, TTWE-3000-01
230V Tower Models: TTWE-1000-02, TTWE-1500-02, TTWE-2000-02, TTWE-3000-02
120V Rack-Mount Models: TRME-1000-01, TRME-1500-01, TRME-2000-01, TRME-3000-01
230V Rack-Mount Models: TRME-1000-02, TRME-1500-02, TRME-2000-02, TRME-3000-02
MODEL & PART NUMBER DESIGNATION - Standard Run-Time Models
120V Tower Models: TTWS-0600-01, TTWS-1000-01, TTWS-1500-01, TTWS-2000-01, TTWS-3000-01
230V Tower Models: TTWS-0600-02, TTWS-1000-02, TTWS-1500-02, TTWS-2000-02, TTWS-3000-02
120V Rack-Mount Models (3U): TRMS-0600-01, TRMS-1000-01, TRMS-1500-01, TRMS-2000-01
230V Rack-Mount Models (3U): TRMS-0600-02, TRMS-1000-02, TRMS-1500-02, TRMS-2000-02
120V Rack-Mount Models (2U): TRMU-0600-01, TRMU-1000-01, TRMU-1500-01, TRMU-2000-01, TRMU-3000-01
14. Specifications