 5. Software (Optional) 

 

5.1 Power Monitoring Software 

 

The UPS-MON software (or other power monitoring software) is applied via standard  
RS-232 interface to perform monitoring functions. The cable must be connected from the 
UPS end to a REMOTE PORT on the computer end. It can be either be COM 1 or COM 2. 
It provides an orderly shutdown of a computer in the event of a power failure. Moreover, 
UPS-MON displays all the diagnostic symptoms on the monitor, such as Voltage, 
Frequency, Battery level and so on. The software is available for Windows XP, 7,8, 10, 
Server-2000,  2003,  2008,  2012 and Linux. Call Marathon Power technical support for 
assistance on OS. 

 

 
5.2 Interface Kits 

A series of interface kits are available for operation systems (Such as PLC, SCADA, signal 
controllers, etc.) that provide UPS monitoring. Each interface kit includes a special interface 
cable required to convert status signals from the UPS into signals which the individual 
system recognizes. The interface cable from the UPS end must be connected to a REMOTE 
PORT on the computer end. It can be either be COM 1 or COM 2. For other installation 
instructions and powerful features please refer to READ.ME file. 

Attention:

 Use only the cable supplied by factory or authorized UPS monitoring cable! 

 

5.3 The characteristics of computer interface port 

The computer interface port has the following characteristics: 

  The communication port located on the bottom of the UPS may be connected to a 

host computer. This port allows the computer to monitor the status of the UPS and 
control its operations in some cases. Its major functions normally include some or all 
of the following: 
a.  To broadcast a warning when power fails.  
b.  To close any open file before the battery is depleted. 
c.  To turn-off the UPS. 

 

 

Some computers are equipped with a special connector to link with the 
communication port. In addition, a special plug-in cord may be needed. Some 
computers may need special UPS monitoring software. Contact Marathon Power for 
details on the various interface Kits.

 

 
 

Содержание SDRS-0300-H1

Страница 1: ...DIN Rail Uninterruptible Power System User Manual for Models SDRS 0300 H1 SDRS 0300 H2 SDRS 0500 H1 SDRS 0500 H2 300W 500W...

Страница 2: ...2...

Страница 3: ...3 Table of Contents Section Page Safety Instructions 4 Introduction 4 1 Presentation 5 2 Installation 6 3 Operation 7 4 Alarm 7 5 Software 8 6 Troubleshooting 9 7 Specifications 10 8 Warranty 11...

Страница 4: ...onnect charging source prior to connecting or disconnecting battery terminals CAUTION Risk of Electric Shock UPS equipment outputs remain live with main disconnect in off position Battery replacement...

Страница 5: ...ion c If the unit shuts down due to overload the LED and alarm will continue for two minutes 3 BATTERY MODE Indicator Yellow LED The LED will illuminate when the UPS is supplying battery power to the...

Страница 6: ...serviceable parts Hazardous live parts inside this unit are energized from the battery supply even when the input AC power is disconnected 2 3 Utility power The terminal block is used to hardwire the...

Страница 7: ...operation the alarm would stop Attention In the BACKUP mode the alarm will beep every 2 seconds Slow speed beep Attention The UPS provides mute function for this warning When the beeping sound occurs...

Страница 8: ...ignals which the individual system recognizes The interface cable from the UPS end must be connected to a REMOTE PORT on the computer end It can be either be COM 1 or COM 2 For other installation inst...

Страница 9: ...e PCB call for service Load less than 40W in battery mode Normal condition No load shutdown function is active UPS always in battery mode Loose AC input connection Recheck input connection Blown input...

Страница 10: ...10 seconds 130 at 3 seconds Short circuit protection UPS output cut off immediately BATTERY Type Sealed maintenance free lead acid battery Battery quantity 12V 7 2Ah x 1 12V 9Ah x 1 Typical recharge...

Страница 11: ...ied values They are not intended to function as surge arrestors The UPS is intended to be installed on the load side of the service entrance and has been tested to verify that transient voltage surges...

Страница 12: ...hon Power Inc 2020 MP_DIN Rail User Manual_Jul_2020 Marathon Power Inc 2020 2538 E 54th Street Huntington Park CA 90255 Office 310 689 2328 Fax 310 689 2329 support marathon power com www marathon pow...

Отзывы: