1.4. Error display
See the table below for descriptions of the displayed errors and countermeasures for these.
If multiple errors occur, only one item is displayed.
The priority order is
w
,
e
,
r
,
t
,
y
,
q
.
Condition
States
Display
TROUBLE SHOOTING
q
Firm Check
NG
(
#
: 1/2/3/4)
The model name, brand name and region information
written in the firmware are compared to the region
settings in the PCB. This error is displayed if the infor-
mation does not match.
" ▲ " is displayed as the first character if the firmware
is not correct (see the illustrations on the right).
L1
FIRM
L2
ERROR
L3
L1
MAIN
–
L2
****
L3
BL-**.**
L1
DSP#
–
L2
ERROR
L3
**.**
L1
A.PLD
–
L2
L3
**.**
L1
V.PLD
–
L2
L3
**.**
L1
GUI
–
L2
********
L3
• Check the resistor for setting the
region(R1590 / R1589, DIGITAL PCB).
• Write the firmware for the correct
region.
w
IP SCALER NG
An error occurs in Loop back Test of the DDR memory
which is performed during the initial setting of i/p
Scaler(ADV8003).
L1
IP
L2
SCALER
L3
ERR 01
• Check the circuits around the IP
SCALER (IC401, DIGITAL PCB) and
DDR2 (IC402/IC403).
If there appear to be no problems,
IC401 or IC402/IC403 is faulty.
During the initial setting of i/p Scaler ( ADV8003 ) ,
there is not the reply of the Loop back Test result of
the DDR memory .
L3
ERR 02
e
GUI Serial
Flash NG
If the Main CPU version is not supported by the GUI
Serial Flash (ADV8003).
" ▼ " is displayed as the first character of the GUI
firmware version.
L1
GUI VER.
L2
ERROR
L3
• Check the firmware version.
Go to next page.
s
134
Caution in
servicing
Electrical
Mechanical
Repair Information
Updating