Error
Code
USB Update Error
Display
Details of Error code
Remedies
60
Error**60
NACK received in response or
no response from Sub for the
"P" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
61
Error**61
Mismatched Check Sum in
response or no response from
Sub for the "I" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
62
Error**62
Failed to start up Sub in
Power On sequence during
Update.
Unplug and reconnect the AC plug, and
try again.
63
Error**63
Failed to transit to Application
Mode.
Unplug and reconnect the AC plug, and
try again.
64
Error**64
Failed to transit to Boot
Loader Mode.
Unplug and reconnect the AC plug, and
try again.
80
Error**80
Write Enable Latch Bit not
set in Read after issuing the
"WREN" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
81
Error**81
Block Erase failed in Read after
issuing the "BE" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
82
Error**82
No Update Packet received
from CY920 (Time Out).
Unplug and reconnect the AC plug, and
try again.
83
Error**83
Abnormal data in Update
Packet received from CY920
(CRC Error).
Unplug and reconnect the AC plug, and
try again.
84
Error**84
Abnormal data in Update
Packet received from CY920
(Packet No Error).
Unplug and reconnect the AC plug, and
try again.
85
Error**85
Setup failure of the XModem
transfer method
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
86
Error**86
Mismatched Check Sum in
Check Sum comparison after
rewriting.
Unplug and reconnect the AC plug, and
try again.
Error
Code
USB Update Error
Display
Details of Error code
Remedies
A2
Error**A2
Unable to detect USB.
Reinsert or try a new USB device, Un-
plug and reconnect the AC plug, and
try again.
A3
Error**A3
No Firmware File in USB.
Check the file, Unplug and reconnect
the AC plug, and try again.
A4
Error**A4
The Firmware File in the USB
does not support your model
and area.
Make sure the model name and area of
the Firmware File, Unplug and recon-
nect the AC plug, and try again.
A6
Error**A6
Error notification received
while requesting the Firm-
ware Info.
Try a new USB device, Unplug and
reconnect the AC plug, and try again.
A7
Error**A7
Time Out while obtaining
Firmware information.
Unplug and reconnect the AC plug, and
try again.
AE
Error**AE
Unable to detect USB for
Firmware Download.
Reinsert or try a new USB device, Un-
plug and reconnect the AC plug, and
try again.
AF
Error**AF
No Firmware File for Firmware
Download.
Check the file, Unplug and reconnect
the AC plug, and try again.
B1
Error**B1
Time Out in Download (writ-
ing to SDRAM) for Firmware
Download.
Unplug and reconnect the AC plug, and
try again.
B2
Error**B2
Error notification received af-
ter rewriting the CY920 Firm.
Unplug and reconnect the AC plug, and
try again.
B3
Error**B3
Error in Firmware Update
(Time Out).
Unplug and reconnect the AC plug, and
try again.
B4
Error**B4
Failed to transit to Boot
Loader Mode.
Unplug and reconnect the AC plug, and
try again.
B5
Error**B5
Failed to transit to Application
Mode.
Unplug and reconnect the AC plug, and
try again.
---Checking the firmware version after updating---
After updating the firmware, check the version.
See "
192
Caution in
servicing
Electrical
Mechanical
Repair Information
Updating