Error
Code
DPMS Update Error Display
Details of Error code
Remedies
56
A P L D
5 6
D o w n l o a d
f a i l e d
Error(NG) notification received
while requesting Firmware Down-
load.
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
57
A P L D
5 7
D o w n l o a d
f a i l e d
Error(Server Busy) notification re-
ceived while requesting Firmware
Download.
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
58
A P L D
5 8
D o w n l o a d
f a i l e d
Error(Connect failure) notification
received while requesting Firm-
ware Download.
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
5A
A P L D
5 A
C o n n e c t
f a i l e d
Invalid DeviceID in response or
no response from Sub for the "C"
command.
Turn off and on the power. Updating
starts automatically.
5B
A P L D
5 B
U p d a t i n g
f a i l e d
NACK received in response or
no response from Sub for the "L"
command.
Turn off and on the power. Updating
starts automatically.
5C
A P L D
5 C
U p d a t i n g
f a i l e d
No Update Packet received from
CY920 (Time Out).
Turn off and on the power. Updating
starts automatically.
5D
A P L D
5 D
U p d a t i n g
f a i l e d
Abnormal data in Update Packet
received from CY920 (CRCError).
Turn off and on the power. Updating
starts automatically.
5E
A P L D
5 E
U p d a t i n g
f a i l e d
Abnormal data in Update Packet
received from CY920 (PacketNo-
Error).
Turn off and on the power. Updating
starts automatically.
5F
A P L D
5 F
U p d a t i n g
f a i l e d
Setup failure of the XModem
transfer method.
Turn off and on the power. Updating
starts automatically.
60
A P L D
6 0
U p d a t i n g
f a i l e d
NACK received in response or
no response from Sub for the "P"
command.
Turn off and on the power. Updating
starts automatically.
61
A P L D
6 1
U p d a t e
C h e c k N G
Mismatched Check Sum in re-
sponse or no response from Sub
for the "I" command.
Turn off and on the power. Updating
starts automatically.
80
G U I
8 0
U p d a t i n g
f a i l e d
Write Enable Latch Bit not set in
Read after issuing the "WREN"
command.
Turn off and on the power. Updating
starts automatically.
81
G U I
8 1
U p d a t i n g
f a i l e d
Block Erase failed in Read after
issuing the "BE" command.
Turn off and on the power. Updating
starts automatically.
82
G U I
8 2
U p d a t i n g
f a i l e d
No Update Packet received from
CY920 (Time Out).
Turn off and on the power. Updating
starts automatically.
83
G U I
8 3
U p d a t i n g
f a i l e d
Abnormal data in Update Packet
received from CY920 (CRCError).
Turn off and on the power. Updating
starts automatically.