11
AUTOMATIC RECORD LEVEL TAPE
DUBBING
1. By pressing the CD STOP/EJECT button and the tape eject
button you can load the CD to be dubbed onto the CD tray and
a recordable tape into the tape transport. Gently press the front
of each of the mechanism to close them. The CD display will
register the general CD data and the tape play indicator located
inside of the Tape PLAY button will begin to flash.
2. Prepare the tape for dubbing by rewinding it to the beginning of
the first side that the tape is to be recorded onto.
3. Set the ALC switch to the ON position.
4. Press the DUBB button once. The REC indicator will begin to
flash, the DUBB indicator will light and the CD player will enter
play mode. The CD will automatically begin to search the
source for the peak level. This procedure could take as long as
5 minutes tocomplete. Once the peak level has been deter-
mined, the record level for dubbing will be set automatically.
5. After the record level has been set, the tape transport will enter
into the record mode. After approximately 5 seconds the CD
player will enter the playback mode and begin to play the first
track, dubbing it onto the tape.
6. When either the CD transport or the tape transport have
reached the end and stopped, the other transport will also stop.
7. To end the dubbing during a session, press the STOP on the
tape transport or the STOP/EJECT button on the CD player.
Notes:
When dubbing is started with a program of CD tracks, the
tracks are dubbed in the order that the original playback
was programmed for. For assistance in programming play-
back, see the section marked “Program Playback”.
During dubbing, a blank space of approximately 4 seconds is
automatically inserted between CD tracks. This may hinder some
dubbing such as live recordings on CD.
The CD peak level that is detected during ALC level dubbing may
vary from one recording to another, however the effect will be
minimal.
When recording with the reverse mode control set to the two way
or the continuous mode there may be an interruption in recording
of approximately 1 second during the optical reversing of the tape
transport.
EXTENDED CASCADE OPERATION
By using the cascade feature on the PMD350 with other PMD350’s
or other Marantz products offering the cascade feature, several
units can be connected to supply long playback or recording
functionality.
EXTENDED CASCADE PLAYBACK
1. Refer to the user guide of the other components to assure that
all connections and switch settings are set correctly.
2. Assure that the “EXT” jack on the rear of all units are connected.
Starting with the first unit to operate, connect the “EXT” out
jack to the “EXT input on the second unit to operate. Continue
this set-up procedure until all units that are to operate in the
cascade mode have the “EXT” control jacks serially linked
together.
3. Set the PMD350 reverse mode control switch to the cascade
position.
4. Begin the playback of the first source by pressing the play
control button. The unit will enter playback mode. After the first
source has completed playback, the next component in the
cascade will begin playback. This will continue until the last unit
linked in the cascade chain has completed playback and entered
the stop mode.
5. To exit out of the cascade playback mode, press the stop control
button of the source machine currently in playback mode.
EXTENDED CASCADE RECORDING
1. Refer to the user guide of the other components to assure that
all connections and switch settings are set correctly.
2. Assure that the “EXT” jack on the rear of all units are con-
nected. Starting with the first unit to operate connect the
“EXT” out jack to the “EXT input on the second unit to operate.
Continue this set-up procedure until all units that are to operate
in the cascade mode have the “EXT” control jacks serially
linked together.
3. Set the PMD350 reverse mode control switch to the cascade
position.
4. Place all components that are linked together in the cascade
mode into the record pause mode.
5. Begin the recording of the first source by pressing the play
control button. The unit will enter record mode. After the first
source has completed recording, the next component in the
cascade will begin recording. This will continue until the last unit
linked in the cascade chain has completed recording and
entered the Stop mode.
6. To exit out of the cascade record mode, press the stop control
button of the source machine currently in record mode.
NOTES:
If all components have not be set up correctly, tape or CD
loaded, record pause armed, etc., the cascade function will
stop upon reaching this source machine.
If the cascade function is started with the tape first the PMD350
will go to CD playback next and then to the next component. If the
playback is started with the CD first the PMD350 will play the CD
then go to the next component.
Before beginning the cascade record function hand wind the tape
leaders so that no leader is showing. This will minimize interrup-
tions in your recordings.