Check item(22).
Check the SPI communication line :
Check the CPU.
Is the "
SPI" waveform of the TP near the DSP [
U1021
] correct (like
the one shown in the diagram) when the power is turned on?
U1021
D_CK 3pin
D_MOSI 4pin
D_CS 6pin
D_MISO 5pin
Check item(23).
Check the SPI communication line :
Check DSP [
U1021
], CPU[
U1013
] patterns as well as soldering.
If there is no problem, go to the next step.
Check the SPI communication line.
DSP [
U1021
] is faulty.
Replace with a new device.
YES
*The diagram shows an example.
(Signal patterns vary depending on the
timing.)
Points for checking waveforms
- Crest value (3.3 V normally)
- Signal change
- CLOCK frequency (about 6 MHz)
Voltage scale:2.0V/div
Time scale:2us/div
NO
YES
Recheck from
check item (1).
If it does not work, replace the PCB.
88
Caution in
servicing
Electrical
Mechanical
Repair Information