background image

Delay page 

– from this page it is possible to set the Output Channels Delay Time from

000

.

0000mS up to 848

.

9984mS, by steps of 1mS or 20

.

8uS.

To set the Delay time press ENTER an arrow will appear on the left of the screen 

->

.

then use

the 

PM2

encoder to set the Delay Time in steps of 1mS and the

PM3

,

for setting the 

fine

Delay Time in steps of 20

.

8 microseconds

.

The following is an example screen for the 

Delay

page where the Delay Time of Output Channel

1 is set to 160

.

1872mS

:

Polarity page

 

from this page it is possible to set the Output Channels Polarity

,

by using the

PM3

encoder

.

The polarity can be

Normal

or

Inverted

(

which means rotated of 180 Degrees

).

The following is an example of a

Polarity

screen where the Polarity of Output Channel 1 is set to

Normal

Peak Limiter sub

-

menu

 – from this page it is possible to set the Output Channels Peak Limiter

.

 

The following is an example screen for the  Peak  Limiter page where the Attack Time of the  Peak
Limiter is set at 5ms

,

the Release Time is set at 0

.

2Sec and the 

Peak  Limiter Active Threshold is

set at

+

15dB

:

Once pushing ENTER the  Peak Limiter

'

s parameters can be modified using the

NAV

/

PM1

,

PM2

and 

PM3

encoders for editing the Peak Limiter

'

s Attack Time [A

].,

Release Time 

[

R

]

and Active  

Threshold

.

Once pushing ENTER the above screen will change as follows

:

The Attack Time [A

]

can be edited using the

NAV

/

PM1

encoder

,

the Release Time [R

]

the

PM2

encoder and the Peak Limiter Active Threshold the

PM3

encoder

.

OutputA Left

Limiter

A

:

5ms    R

:

0

.

2s   +15

.

0dB

OutputA Left

Limiter

->

A

:

5ms    R

:

0

.

2s   +15

.

0dB

OutputA Left

Polarity

->

Polarity  =   Normal

OutputA Left

Delay

->

Delay  =  160

.

1872mS

26

Содержание CLP-2600

Страница 1: ...19 482mm DIGITAL USB...

Страница 2: ...unit Refer all servicing to qualified service personnel To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous vo...

Страница 3: ...ibility to store recall up to 20 presets but is coming with no factory presets After the initialization the CLP2600 will show on the LCD the current preset if any available otherwise if no presets ava...

Страница 4: ...two seconds Input Channels LIN or RIN are either muted or unmuted The red LED will illuminate when the Channel is muted When the MUTE LED is OFF then the related Input Channel is UN MUTED A momentary...

Страница 5: ...0 2 UTILITY MENU Program Utilities 2 1 PROGRAM UTILITY Recall a Program Recall a Program 01 Preset 01 24 Preset 24 2 2 PROGRAM UTILITY Save a Program Save a Program 01 Preset 01 24 Preset 24 2 3 PROG...

Страница 6: ...n selected a Bell filter just defining its Bandwidth BW to be greater then 0 then the Bell filters can be set by the following parameters 3 1 Output A B Left Right EQ X up to 5 filters available 1 00k...

Страница 7: ...f On 3 Output A B Left Right AGC AGC Exp Time 1 500S AGC Exp Time 1 500S PM1 N A PM2 N A 0 057S 14 400S 4 Output A B Left Right AGC AGC Cmp Time 0 500S AGC Cmp Time 0 500S PM1 N A PM2 N A 0 014S 6 000...

Страница 8: ...mp Rto 4 1 PM1 N A PM2 N A 1 1 16 1 10 Output A B Left Right Delay Delay 0 000 ms Delay 0 000 ms PM1 N A 000 0000mS 000 0000mS 1 ms steps 20 8 us steps 848 0000mS 000 9984mS 11 Output A B Left Right P...

Страница 9: ...if selected the number of bands in the editing environment of the Compressor 1 the choice will be replicated on the editing environments of the Compressors 2 3 So if selected the Monoband Compressor f...

Страница 10: ...shold 3dBu Threshold 3dBu PM1 N A PM2 N A 8dBu 20dBu 7 Output A B Left Right Cmp1 Ratio 2 1 Ratio 2 1 PM1 N A PM2 N A 1 1 32 1 8 Output A B Left Right Cmp1 Knee Soft Hard 0 Knee Soft Hard 0 PM1 N A PM...

Страница 11: ...er as the currently selected running option System Utilities Sub menu this sub menu allows to access several operations related to the CLP2600 Start Up and General Configuration From the System Utilit...

Страница 12: ...ement is Time milliseconds Input Routing the CLP2600 Processor is equipped with 2 Analog Inputs Balanced Female XLR and a stereo S PDIF Digital Input RCA connector The Routing Options page allows you...

Страница 13: ...the following If presets have previously been stored by the user anyone of them can be recalled By using the PM3 encoder it is possible to scroll through the stored presets Once the desired preset app...

Страница 14: ...page the User can enter a Preset Name up to 16 Characters by using the PM3 encoder to choose a character and the NAV PM1 encoder to move between the 16 available locations for the character s positio...

Страница 15: ...y time it is possible to quit the storing action by pressing the ESC button Delete a Program this page allows you to delete a preset already stored in the CLP2600 memory By pressing the ENTER button a...

Страница 16: ...ote control interface USB or RS485 to be used for controlling the CLP2600 From Interface Utilities press ENTER to access the Interface Setup Interface Setup this screen allows you to choose the remote...

Страница 17: ...r to move between available locations you can enter a 6 Character Password Name The current position of the cursor for the characters to be entered is shown by a blinking underscore During this editin...

Страница 18: ...t screen adding on the lower row at the extreme right of the LCD the icon of a LOCK To Unlock the CLP2600 it is enough to enter again the Unit Lock Menu and provide the proper Password Note originally...

Страница 19: ...UTE the input it is enough from the MUTE condition to press again the Eq Edit Mute button for more than 3 seconds Note All parameter editing can be done using the NAV PM1 PM2 and PM3 encoders and the...

Страница 20: ...el Filter 12dB Oct Slope Butwrth 18dB Butterworth Filter 18dB Oct Slope Butwrth 24dB Butterworth Filter 24dB Oct Slope Lnk Ril 24dB Linkwitz Riley Filter 24dB Oct Slope Bessel 24dB Bessel Filter 24dB...

Страница 21: ...e it is necessary to have the filter s GAIN 0 0dB then using the PM2 encoder rotate it clockwise in order to decide the Peaking filter s Bandwidth or counter clockwise to select the Shelving filter ty...

Страница 22: ...Center Frequency of the Parametric Filter can be edited using the NAV PM1 encoder the BW the PM2 encoder and the Gain the PM3 encoder Center Frequency the selectable frequencies range is from 20Hz to...

Страница 23: ...PM1 encoder Note Once the desired High Shelving filter is selected the PM3 can then be used to select the desired GAIN and when the GAIN is set at a value different from 0 0dB then the filter type can...

Страница 24: ...from the BYPASSED condition to press again the Lim Comp Edit Bypass button for more than 3 seconds Note All parameter editing can be done using the NAV PM1 PM2 and PM3 encoders and the current shown v...

Страница 25: ...on level when the averaged signal is beyond a defined Threshold Thr Hold The AGC implemented in the CLP2600 is acting on the evaluation of an input signal which is ana averaged one on a 50ms time fram...

Страница 26: ...ress ENTER an arrow will appear on the left of the screen then use the PM3 encoder The following is an example screen for the AGC Bypass page where the AGC is set Active AGC Exp Time page from this sc...

Страница 27: ...t not higher than 1 If the Expansion Ratio is set to 2 the signal can be expanded up to a max amplitude that is twice the original one The following is an example screen for the AGC Exp Ratio page whe...

Страница 28: ...here the Polarity of Output Channel 1 is set to Normal Peak Limiter sub menu from this page it is possible to set the Output Channels Peak Limiter The following is an example screen for the Peak Limit...

Страница 29: ...the PM3 encoder Note The Peak limiter Threshold is defined in Vp due to the fact that with both Sinusoid and Squared wave testing signals the CLP2600 Peak Limited output Vp Peak Peak Level is the sam...

Страница 30: ...gain the Lim Comp Edit Bypass button for more than 3 seconds Note All parameter editing can be done using the NAV PM1 PM2 and PM3 encoders and the current shown value of the selected option is AUTOMAT...

Страница 31: ...he 2 bands The buttons order is set so to be the number one the button locate at the most far left position from the LCOMP RCOMP labels Band Mode page from this page it is possible to set CLP2600 way...

Страница 32: ...d on the CrossOver 2 editing page The following is an example screen for the CrossOver 1 page where theCross Over frequency is set to 250Hz CrossOver 2 page when the CLP2600 is set in Mono Mode 1 band...

Страница 33: ...the input signal itself so to make more Musical the Compressors action The RMS Compressor it is so maintaining constant the output energy and not the Output peak so to have for the different inputs in...

Страница 34: ...Time the selectable range of the RMS Compressor s Release Time is from 0 1s to 3s in steps of 0 1s Threshold page from this page it is possible to set the T hreshold parameters of the RMS Compressor O...

Страница 35: ...ompressor s Knee editing page can be entered and using the PM3 encoder the Ratio parameter can be set Drive the selectable range of the RMS Compressor s Drive is from 12dB up to 6dB by steps of 0 5dB...

Страница 36: ...bar of led meters is showing when turned on the Lim led that the Peak Limiter is active and limiting the output signal with the Clip led an occurring Clip on the output signal and with the other leds...

Страница 37: ...evel 20dBu Analog Output Signal Ch1 Ch2 Bal Male XLR Maximum Output Level 20dBu Digital Processing DSP SAM3716 24bits data x 96 bits coeff A D Converters AKM5392 24bits D A Converters AKM4396 24bits S...

Страница 38: ...Http www marani com cn MAINS...

Отзывы: