symptoms
probable Causes
Solutions
The motors do not work The control unit is not
powered
Check the connection of the control box to
power supply.
Check that the power supply is properly
connected to the mains
The motors operate at
low speed
Learning problem
Repeat the learning procedure (see manual)
The motors do not slow
down at the end of the
stroke
Learning problem
Repeat the learning procedure (see manual)
The shutters do not
move during the
learning process
Start the learning cycle
when the shutters are
open
Close the shutters and repeat the learning cycle
(see manual)
The shutter with
overlap is the first to
close
Motor 1 and motor 2
connections inverted
Toggle the switch to change direction located on
the product (see instructions)
Wired version: press
closing the shutters
open
Bad connection of the
command button
Check the connection of the button (see
instructions)
Pressing closing a
shutter opens, other
closes
Bad connection of the
motor 2
Invert the connection the motor 2 (see
instructions)
Pushing open the
shutters are closing
Bad connection of the
command button
Check the connection of the button (see
instructions)
Pressing opening a
shutter opens, other
closes
Bad connection of the
motor 2
Invert the connection the motor 2 (see
instructions
The shutter begins its
course and returns to
its position
Presence of an
obstacle
Remove the obstacle
The shutter goes too
far at the close
No end stops
Check for a stop shutters top and bottom
The motor rotates but
the shutter does not
open (or not close)
Connecting sleeve
hinge broken or
missing.
Put a sleeve
The motors are not
running on a request
for opening or closing
The control is defective
For wired, check the connection of the button.
For the radio, check that the batteries are not
defective (The LED should light pressure on
The shutter does not
close and / or does not
open completely The
shutter does not close
and / or does not open
completely
The rail is incorrectly
mounted
Check the mounting of rail (see instructions)