8.2 To exit from the Analogue remote control mode
Press the [Lock/ Unlock] button (10) to exit from the Analogue Remote Control Mode.
Take note of the orange [REMOTE] LED is OFF.
8.3 Method A
Using two external variable DC voltage sources.
Remote socket pin assignment for external variable voltage source.
CC current setting by remote control.
Adjust the CC current using external power supply connected to Pin 3 and pin 4
(Ground).
Output voltage setting by remote control.
Check the output voltage range of the power supply by varying the external voltage
source connected to Pin 2 and Pin 4 (Ground).
Remote socket pin assignment for external variable voltage source
PIN
FUNCTION
REMARKS
1
Internal DC +5V
Less then 50mA
2
Voltage Adjust
0-5V
3
Current Adjust
0-5V
4
Ground
5
Output OFF
Short to Ground
6
Fault signal for OVP, OTP
Output 5V/ 50mA max. for
External alarm device
7
N.A.
8
N.A.
Remark:
Only connects to internal ground (pin 4) for all analog remote control functions.
Don't connect to the unit output negative, otherwise it may damage the unit.