Manson Engineering Industrial KPS-6000 Series Скачать руководство пользователя страница 2

Table of Contents 

 

1. 

PRECAUTIONS   

 

 

 

 

 

 

 

 

 

1.1  Warning:   

 

 

 

 

 

 

 

 

 

1.2  Caution:   

 

 

 

 

 

 

 

 

 

1.3  Copy Right  

 

 

 

 

 

 

 

 

 

1.4  Operation Environmental Condition: 

 

 

 

 

 

2. 

ACCESSORIES 

 

 

 

 

 

 

 

 

 

 

3. 

INTRODUCTION   

 

 

 

 

 

 

 

 

 

4. 

SPECIFICATIONS   

 

 

 

 

 

 

 

 

5 - 9 

 

5. 

INDICATORS and CONTROLS   

 

 

 

 

 

 

10 - 11 

 

5.1  Back Panel  

 

 

 

 

 

 

 

 

12 

 

6. 

OPERATION PROCEDURES   

 

 

 

 

 

 

12 

 

6.1  Adjusting Output Voltage and Current   

 

 

 

12 

 

6.2  Upper Voltage and Current Limit Adjustment   

 

 

13 

 

6.3  Select and Adjust 3 Preset Value of Voltage and Current   

14 

 

6.4  Output ON/OFF (Include Power up ON/OFF Setting)  

 

14 

 

6.5  Lock/Unlock of Front Panel   

 

 

 

 

 

15 

 

6.6  Watt-meter and Amp-meter Selection   

 

 

 

15 

 

6.7  Ramp UP/DOWN Generator   

 

 

 

 

 

16 - 21 

 

6.8  Factory Reset 

 

 

 

 

 

 

 

 

21 

 

6.9  Remote Control Interface Selection 

 

 

 

 

22 

 

6.10  Change Display Brightness   

 

 

 

 

 

22 

 

6.11  Voltage and Current setting Timeout Time 

 

 

 

23 

 

7. 

MENU FLOW 

 

 

 

 

 

 

 

 

 

24 

 

8. 

ANALOGUE REMOTE CONTROL MODE   

 

 

 

 

25-28 

 

 

 

 

 

 

 

 

 

Содержание KPS-6000 Series

Страница 1: ...KPS 6000 series REMOTE PROGRAMMABLE POWER SUPPLY WITH ETHERNET NETWORK CONNECTIVITY DC WAVE FORM GENERATOR 3 SELECTABLE VOLTAGE CURRENT RANGES USER MANUAL REV 2 2022 03 7673 6600 0001...

Страница 2: ...urrent 12 6 2 Upper Voltage and Current Limit Adjustment 13 6 3 Select and Adjust 3 Preset Value of Voltage and Current 14 6 4 Output ON OFF Include Power up ON OFF Setting 14 6 5 Lock Unlock of Front...

Страница 3: ...the original fuse 1 2 Caution Failure to observe this warning may result in damage to equipment and Improper functioning of the power supply 1 Use a grounded 3 pin AC source 2 This unit is for indoor...

Страница 4: ...an optional Ethernet interface card allows users to configure control or monitor basic power supply settings over the internet KPS uses SCPI Standard Commands of Programmable Instruments syntax for ea...

Страница 5: ...play 0 2 3 counts Input Voltage 90 264V 50Hz Full Load Input Current 230VAC 1 1A 1 1A 0 95A Efficiency 82 82 82 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Speed...

Страница 6: ...3 counts Input Voltage 90 264V 50Hz Full Load Input Current 230VAC 2 2A 2 2A 1 8A Efficiency 83 84 85 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Speed Protectio...

Страница 7: ...3 counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 2 6A 2 6A 2 6A Efficiency 84 85 85 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full S...

Страница 8: ...counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 3 5A 3 5A 3 2A Efficiency 84 85 87 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Sp...

Страница 9: ...counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 5 0A 4 9A 4 5A Efficiency 86 5 89 87 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full...

Страница 10: ...supply will be working in this mode while the loading current is least than the set current 6 Constant Current Mode Indicator Indicate the Power Supply is working in Constant Current mode The output c...

Страница 11: ...ttons will be used The second function of buttons include V t A W UVL UCL 12 Output ON OFF Ramp UP DOWN Program Running Button Press this button to switch the output ON and OFF This button ON indicate...

Страница 12: ...Voltage Knob clockwise to INCREASE output voltage Rotate Voltage Knob anti clockwise to REDUCE output voltage Press Voltage knob to switch between COARSE and FINE adjustment When press the knob the di...

Страница 13: ...UVL adjustment Press and the button will ON Then press Voltage knob The display will show as follow Rotate Voltage knob to adjust the value Press to confirm setting If the new UVL value is lower than...

Страница 14: ...re1 Pre2 Pre3 To adjust value of preset program After preset program is selected use Voltage and Current knob to adjust value for that preset program The setting will be saved automatically The value...

Страница 15: ...ck of Front Panel In case the front panel is locked only the has function Other buttons and knobs are being locked The front panel will be locked in two conditions a Manually press to LOCK the front p...

Страница 16: ...select dvdt menu The display show Step 3 Press Volt knob to enter dvdt setting The display show Step 4 Rotate Volt knob to set items Step 5 Rotate Curr knob to change value of set items The below tabl...

Страница 17: ...tting Value Set item Value Explanation 2 Set 2 steps to run Step 1 and Step 2 3 Run 3 cycle only 2 5 Set Step 1 voltage to 2 5V 5 Set Step 1 current to 5A 3 Set Step 1 run time to 3s Ramp UP from step...

Страница 18: ...p 2 6 Run 6 cycle only 2 5 Set Step 1 voltage to 2 5V 5 Set Step 1 current to 5A 3 Set Step 1 run time to 3s Ramp UP from step 1 voltage to step 2 voltage in 3s 12 Set Step 2 voltage to 12V 10 Set Ste...

Страница 19: ...o step 2 voltage in 0s 12 Set Step 2 voltage to 12V 10 Set Step 2 current to 10A 3 Set Step 2 run time to 3s Keep at 12V by 3s since step 2 voltage step 3 voltage 12 Set Step 3 voltage to 12V 7 Set St...

Страница 20: ...to 10A 5 Set Step 2 run time to 5s Keep at 12V by 5s since step 2 voltage step 3 voltage 12 Set Step 3 voltage to 12V 7 Set Step 3 current to 7A 4 Set Step 3 run time to 4s Ramp UP from step 3 voltag...

Страница 21: ...voltage step 1 voltage 6 8 Factory Reset The Factory reset feature is reset the Preset program UVL UCL to factory default setting Steps for Factory reset Step 1 Press and hold button to enter setting...

Страница 22: ...erface Step 5 Press VOLT knob to return to menu mode Step 6 Press to exit menu Please reference to software user manual for detail operation of PC control software 6 10 Change Display Brightness The K...

Страница 23: ...e set from 1s to 30s Steps for changing timeout time Step 1 Press and hold button to enter setting menu Step 2 Rotate VOLT knob to select tOUt menu The display shows Step 3 Rotate VOLT knob to enter t...

Страница 24: ...7 MENU FLOW P 24...

Страница 25: ...ires 8 1 Using the analogue remote control mode Set the KPS power supply to Analogue Control Mode AC after all the connections with the 8 pin metal plug is inserted at port 5 at the rear panel 1 Press...

Страница 26: ...Output voltage setting by remote control Check the output voltage range of the power supply by varying the external voltage source connected to Pin 2 and Pin 4 Ground Remote socket pin assignment for...

Страница 27: ...in order for the remote control to be functional Remark variable resistors 5Kohm Remote socket pin assignment for variable resistor PIN FUNCTION REMARKS 1 Internal DC 5V Resistor end 2 Voltage Adjust...

Страница 28: ...shows CC current setting value and the Output ON OFF Button 12 is lit off The current output voltage and current setting will show on the panel meter D You also can adjust the output by voltage curren...