Example 3 Rectangular Waveform
Setting Value:
Set item
Value
Explanation
4
Set 4 steps to run. From Step 1 and Step 4
4
Run 4 cycle only
2.5
Set Step 1 voltage to 2.5V
5
Set Step 1 current to 5A
0
Set Step 1 run time to 0s
(Edge UP from step 1 voltage to step 2 voltage in 0s)
12
Set Step 2 voltage to 12V
10
Set Step 2 current to 10A
3
Set Step 2 run time to 3s
(Keep at 12V by 3s, since step 2 voltage = step 3 voltage)
12
Set Step 3 voltage to 12V
7
Set Step 3 current to 7A
0
Set Step 3 run time to 0s
(Edge DOWN from step 3 voltage to step 4 voltage in 0s)
2.5
Set Step 4 voltage to 2.5V
6.5
Set Step 4 current to 6.5A
5
Set Step 4 run time to 5s
(Keep at 2.5V by 5s, since step 4 voltage = step 1 voltage)
P.19