23
6.3
CLEANING
Clean the blade (Ref. Pic. 5-6-7-8-24)
Pic. 24 – Clean the blade
Clean the blade ring protection (Ref. Pic. 5-6-7-8-25)
Pic. 25 – Clean the blade ring
Clean the disassembled parts
All the parts that have been disassembled as per para.6.2, with the exception of the sharpener, should be
cleaned with neutral detersive/disinfectant.
After having been washed, they should be rinsed with plenty of cleaned water and dried.
To reassemble them use the same procedure as per para.6.2 in reverse mode.
WARNING!
Be carefull during the cleaning of last slice devices, cause they’re equipped with sharp spikes. We
recommend to wear protective gloves and clean them with a semi rigid brush.
Do not use dishwasher for wash the components.
Do not dip the “VX BV SMARTY e VX BVC SMARTY” plate in any liquid that can penetrate inside
and damage the mechanism
Sharpener cleaning must be carried out with a dry brush only. Grinding and finishing wheels too must
be cleaned with brush and solvent only.
Observe the safety data, given for the cleaning compounds in use. Do not damage environment.
Main body cleaning
- Remove coarse product scraps by hand or with a plastic scraper or knife.
- Deep clean with cloth, brush or spray, wetted with a suitable cleaning compound.
- Disinfect with cloth, sponge or spray, wetted with an approved compound.
- Rinse with cloth, sponge, spray and using clean water.
WARNING!
This operation must be done with great attention and
concentration, cause there is danger of cutting.
Disconnect the plug from the socket before cleaning the blade
guard.
- Close the gauge plate by rotating clockwise the knob (4) till the
end of stroke.
- Remove the plate, the blade cover and the slice deflector how
described in section 6.2.
- Press a wet cloth on the front surface of the blade and move it
slowly from the centre outward, while rotating the blade by hand.
- Repeat the operation on the back side of the blade.
- Dry in the same way with a dry and soft cloth
WARNING!
Before cleaning the blade protection, disconnect the slicing machine
from the power supply.
- Close the gauge plate turning the knob (4) till the end of the stroke.
- Remove plate, blade cover and slice deflector how described in section
6.2.
- Place a damp cloth in the space between the blade and ring.
- Holding the cloth in gentle pressure inside the ring, rotate the cloth for
the development of the ring itself.