Operating Manual
PR-101131-0121 Version 180905
13 of 16
R
ESETTING AFTER RELEASE
D
ISMANTLING
When the coupling is taken out of service and dismantled
there is a danger that the fluid will spurt out. Special protective
measures such as personal protection equipment must
therefore be adopted.
a. Wear suitable personal safety equipment.
b. Make sure that the coupling is depressurized
and empty.
V
ISUAL INSPECTION
Screw out the destroyed parts of the breaking bolts.
Check for dirt, seal damage and any obvious physical damage
(such as impacts, etc.).
Tool: wrench size acc. to Table 6, bolt.
O
UTER BODY SEALING RING
Replace the sealing ring on the body with a new one.
Make sure that the seal doesn’t get scratched when
mounting. The open profile should be in the
direction which is shown in the picture.
B
REAKING BOLTS
Replace the bolts only by original spare parts from Mann Tek
with the same breaking force.
Example shows 13 kN breaking bolts