background image

REPAIRS

Small Cuts

Small cuts will eventually gap open. To repair, clean any dirt from the cut and apply MLG-33 seam sealer.

Replacing Damaged Areas – Plugs

If you must replace a damaged area, follow these steps:

    •  Select a design element from the scrap material that matches the design to be removed from the existing resilient.  

    •  Accurately overlay this piece over the damaged area.

    •  Double cut on the inside of the grout line if possible and remove the damaged piece. If the floor covering you are    

      repairing is installed over existing resilient flooring, be careful not to cut too deep.

  • If 

the 

Insight

®

 Plus GB

 was installed FULLY ADHERED, apply a thin layer of MT-711 to the back of the repair piece 

      and place into position.  Roll with a hand roller. Apply MLG-33 seam sealer.  Protect from foot traffic until sealer is   

   fully 

cured.

  • If 

the 

Insight

®

 Plus GB

 was installed Loose Lay, apply a thin layer of MT- 711 on the back of the repair piece as well as  

      under the edges of the repair area. Position the repair piece into the cut out area and lightly roll the area with a hand  

      seam roller. Apply MLG-33 seam sealer. Protect from foot traffic until sealer is fully cured.

Choices that Work.

Questions about warranties? call 800 241 2262 or visit www.manningtoncommercial.com 

July, 2015 

Insight

®

 Plus GB

Installation Guidelines

Insight

®

 Plus GB Instal

lat

ion Guidel

ines

Содержание Insight Plus GB

Страница 1: ...materials for subfloor preparation MATERIAL RECEIVING HANDLING STORAGE 1 Always store Insight Plus GB tightly rolled face out on a sturdy cardboard core designed for that purpose Store the roll horizo...

Страница 2: ...can Corp 757 425 1206 www koesterusa com Mapei 800 426 2734 www mapei com Uzin Ltd 800 505 4810 www ufloorsystems com SUBFLOOR PREPARATION Concrete Careful subfloor preparation is vital for an excelle...

Страница 3: ...ess Have a written warranty for suitability and performance from the panel manufacturer or have a history of proven performance e Any unevenness at the joints between panels must be sanded to a level...

Страница 4: ...placing the Insight Plus GB into the wet tacky MT 711 adhesive with a 1 16 x1 32 x1 32 notched trowel the substrate must be smooth and have sufficient porosity to receive the adhesive For wood substr...

Страница 5: ...o the adhesive to eliminate trapping air Do not drop or flop the material into the adhesive Using a 50 lb or heavier three section floor roller roll the material in both directions starting in the mid...

Страница 6: ...n determining the direction of sheet or fill piece if needed REVERSE METHOD Reverse Sheets for Seaming means turning the second sheet 180 to the first sheet To determine the amount of additional mater...

Страница 7: ...ong the length of the seam You must apply seam sealer into the seam cut and leave a bead of sealer approximately 1 8 wide centered on the seam Remember it is crucial that the seam sealer be applied to...

Страница 8: ...deep If the Insight Plus GB was installed FULLY ADHERED apply a thin layer of MT 711 to the back of the repair piece and place into position Roll with a hand roller Apply MLG 33 seam sealer Protect f...

Отзывы: