2 Safety 

2.1  Warning notes and symbols 

 

This symbol appears in all the 
sections of the manual in which your 
safety could be at risk. Failure to 
observe the information provided 
could put persons at risk. 

 

This symbol appears in all the 
sections of the manual in which the 
information provided must be strictly 
observed to prevent damage to or 
destruction of system parts. 

 

This symbol appears in all the 
sections of the manual in which the 
information provided must be 
carefully observed to ensure trouble-
free, economic operation. 

2.2 General 

information 

Read the EU Material Safety Data Sheet on 
diesel fuel and observe the information 
contained in it regarding handling diesel fuel. 

 

Diesel fuel and fuel fumes are damaging to 
health. 

 

Do not inhale them, let them get in your 
eyes or come into direct contact with bare 
skin. 

 

Only complete assembly work when the 
engine has stopped. 

 

Relieve pressurised lines before starting 
any work. 

 

If fuel escapes, a collecting vessel must be 
placed under the vehicle to prevent 
environmental pollution. 

 

Only complete work for which you have 
been trained and received the necessary 
instruction. 

2.3 Intended 

use 

The various models of the ProVent series are 
exclusively intended for mechanical oil 
separation of blow-by-gas or for crankcase 
ventilation of diesel and gas engines. Any 
other use above or beyond this is considered 
unintended use. The manufacturer/supplier is 
not considered liable for damage resulting 
from unintended use. 
Intended use also includes observing the 
information in the installation and 
maintenance manual and meeting all the 
inspection and  maintenance conditions. 
The operator is obliged to check the ProVent 
once a week for externally recognisable 
damage and defects, and to immediately 
report any changes which have occurred 
(including in the operating behaviour), which 
impair the functional safety. 
All labels and identifications on the ProVent 
must be kept in legible condition. 
The crankcase ventilation system may only 
be serviced by trained and authorized 
personnel. 
All ProVent systems are built according to 
state-of-the-art technology and the 
recognised safety-related rules. However, the 
functional safety of connected equipment can 
be at risk when: 

 

A ProVent system is used improperly, 

 

the operating conditions have changed, 

 

reconstructions have been made without 
prior consultation with the manufacturer, 

 

the necessary maintenance and repair work 
has been neglected. 

Only use models of the ProVent series when 
in proper technical condition and in 
accordance with the technical design in a 
safety and danger-conscious manner while 
observing the installation and maintenance 
manual! Investigate faults (or have them 
investigated) immediately, particularly those 
which could impair safety! 

Содержание ProVent 100

Страница 1: ...ase 0911 MANN HUMMEL ProVent Oil Separator for Open and Closed Crankcase Ventilation Systems Models 100 150 200 400 800 Installation and Maintenance Manual Model 150 Model 150 Model 400 Model 800 Mode...

Страница 2: ...21 6 Technical Data 22 6 1 Dimensions 23 7 Related Documents 28 1 Foreword This Installation and Maintenance Manual is intended to help become familiar with the oil separators of the ProVent series an...

Страница 3: ...by gas or for crankcase ventilation of diesel and gas engines Any other use above or beyond this is considered unintended use The manufacturer supplier is not considered liable for damage resulting fr...

Страница 4: ...r flowing through the oil separator the blow by gas is routed via the outlet fitting into the open In the process overpressure results in the crankcase during operation With a close crankcase ventilat...

Страница 5: ...dustrial Filters 5 Fig 1 Overview of ProVent series 2 3 8 1 1 2 3 1 7 6 3 4 5 5 8 6 8 6 13 ProVent 150 ProVent 200 ProVent 800 ProVent 400 ProVent 100 8 7 11 5 2 10 10 1 7 5 3 2 6 4 8 7 1 2 5 3 6 7 10...

Страница 6: ...ed are damaged please inform MANN HUMMEL immediately The assembly of the ProVent and the installation of the lines may only be carried out by qualified persons instructed for this purpose It is essent...

Страница 7: ...nsured that the existing blow by gases do not endanger persons or objects The ProVent system can be mounted on the engine or the frame of the machine vehicle with the holder 5 The arrow on the ProVent...

Страница 8: ...return fitting Connecting above oil level An optionally available non return valve is required for this connection version The oil return fitting 6 is connected to the non return valve with a drain l...

Страница 9: ...fficient length of hose is pushed on and secure with hose clamps see Chap 4 2and 4 3 Connect the oil return hose and non return valve if necessary to the oil sump To ensure proper functioning the ProV...

Страница 10: ...e to be flexibly adjusted to the installation situation Remove the retaining clip 1 upward from the groove and turn the holder into the desired position Press the holder together somewhat in the desir...

Страница 11: ...position and engage the retaining clip in the groove again Mount the holder in the vertical position Recommended tightening torque for M8 screws 10 Nm Ensure sufficient strength of the screw and nut...

Страница 12: ...crew with the nut Tightening torque 9 Nm Mount the holder in the vertical position Ensure sufficient strength of the screw and nut material Connect the hoses to the inlet 3 outlet 4 and oil return fit...

Страница 13: ...vary greatly depending on the actual oil available and the dirt soot content in the blow by gas 5 2 Changing oil separator element When working on the ProVent place a collecting vessel underneath it...

Страница 14: ...ProVent Ensure correct seating Screw on the lit in the previous position again Tightening torque 4 Nm Reconnect the drain hose if necessary Fig 11 Changing oil separator of ProVent 100 ProVent 150 Det...

Страница 15: ...oil separator of ProVent 150 ProVent 200 Screw off the lid in the direction of the arrow of the lid marking If the lid is difficult to remove use a suitable aid see Fig 14 Fig 14 Detaching lid of Pro...

Страница 16: ...lid in the direction of the arrow of the lid marking Fig 16 Opening lid of ProVent 400 1 If the lid is difficult to remove use a suitable aid see Fig 17 Fig 17 Opening lid of ProVent 400 2 Remove the...

Страница 17: ...with the oil separator element on the housing When doing so watch the position of the inlet and outlet fitting arrows on housing and lid 1 face in the same direction see Fig 20 Press the lid onto the...

Страница 18: ...lid This loosens the lid Fig 22 Removing lid of ProVent 800 Remove the lid with the oil separator element Fig 23 Removing oil separator of ProVent 800 Pull the oil separator element off the lid fittin...

Страница 19: ...MMEL Industrial Filters 19 Place the lid with the oil separator on the housing When doing so watch the position of the inlet and outlet fitting marking see Fig 25 Close the quick connect couplings Fig...

Страница 20: ...t for ProVent 200 LC 5001 X HE LC 5002 X UE Service Kit for ProVent 400 LC 10 001 X HE Service Kit for ProVent 800 LC 16 001X HE HE High Efficient Medium UE Ultra High Efficient Medium New separator e...

Страница 21: ...ing Correct if necessary Conduct maintenance Increased crankcase pressure Separator element exhausted Kinked or clogged hose Conduct maintenance Check hose and correct if necessary Oil drain off not e...

Страница 22: ...ation position vertical Permitted angled position of high axis 45 in all directions Inlet 2 positions 1 position additional on request Positioning Outlet 4 positions can be rotated in 3 steps 12 posit...

Страница 23: ...MANN HUMMEL ProVent MANN HUMMEL Industrial Filters 23 6 1 Dimensions ProVent 100 Holder Rotation in 90 steps possible Outlet Inlet Min element removal height Oil return...

Страница 24: ...MANN HUMMEL ProVent MANN HUMMEL Industrial Filters 24 ProVent 150 Inlet Outlet Min element removal height Oil return Position variable...

Страница 25: ...MANN HUMMEL ProVent MANN HUMMEL Industrial Filters 25 ProVent 200 Min element removal height Inlet Outlet Oil return Holder Rotation in 30 steps possible...

Страница 26: ...MANN HUMMEL ProVent MANN HUMMEL Industrial Filters 26 ProVent 400 Min element removal height Inlet Outlet Oil return...

Страница 27: ...MANN HUMMEL ProVent MANN HUMMEL Industrial Filters 27 ProVent 800 Inlet Outlet Oil return Position variable 360 Min element removal height...

Страница 28: ...NN HUMMEL Industrial Filters 28 7 Related Documents The following documents must also be observed and applied in addition to this Operating and Maintenance Manual Technical data in accordance with res...

Страница 29: ...performance capabilities of the products Filters for the international spare parts market are sold under the names of internationally renowned customer brand names as well as our own MANN FILTER bran...

Отзывы: