Fig. 8 

Secondary element 

(Fig. illustrates size 7) 

 

6.3.3

 

Installing the main filter element 

(Refer to Section 6.2.3) 

6.4

 

Maintenance of the cyclone block 

Blocked cyclone cells (e.g. by blades of grass 
sucked  up)  have  a  lower  level  of  efficiency. 
To ensure a long service life for the main filter 
element,  check  the  cyclone  block  regularly 
and clean it as necessary. 

 

 

Be  careful  not  to  damage  the 
cyclone cell. 

Do  not  use  any  hard  or  sharp-
edged tools! 

 

Unscrew the central bolt (Allen screw  a/f  5, 
Pos. 4). 

 

Pull out the cyclone block fully. 

 

Remove  any  foreign  bodies  and  dust 
deposits  from  the  cyclone  block  and  inside 
the  housing  by  hand  or  by  means  of  a 
brush, for example. 

 

Loosen  stubborn  dust  deposits  on  the 
cyclone  block  by  soaking  in  a  PA6-
compatible cleaning agent and remove with 
a water jet. 

 

Blow  the  cyclone  block  dry  to  prevent  new 
dust accumulating again. 

 

Slide the cyclone block in the housing. 

 

Screw in the Allen screw with washer (Ma = 
6 +/- 2 Nm). 

 

Slide  the  inner  housing  section  in  the 
cyclone block housing. 

 

Screw  in  the  hexagonal  screw  and  washer 
(Ma = 6 +/- 2 Nm). 

 

7

 

Storing Filter Elements  

 

 

Protect  filter  elements  in  storage  from  exposure  to  dust,  moisture  and  damage.  
It is preferable to keep them stored in their original packaging. 

It is practical to keep at least one spare element in stock for each filter element used. 

 

 

Seal 

Frame

 

Handle 

Содержание IQORON 10

Страница 1: ...Version 0709 MANN HUMMEL IQORON 7 10 12 14 Installation and Maintenance Manual...

Страница 2: ...block 10 7 Storing Filter Elements 10 8 Troubleshooting 11 9 Disposing of Parts 12 1 Foreword This installation and maintenance manual serves to help you become familiar with the IQORON and its intend...

Страница 3: ...eyond this such as filtering aggressive combustible and or explosive materials is considered unintended use The manufacturer supplier is not considered liable for damage resulting from unintended use...

Страница 4: ...the filter must be serviced The secondary element Pos 10 protects the engine from penetration by dust during maintenance and to a certain extent during operation with a main filter element damaged th...

Страница 5: ...comparable Pos Name Pos Name 1 Lid 7 Connection for maintenance indicator switch 2 Main filter element 8 Clean air connection 3 Cyclone block 9 Wire clamp fastener 4 Allen screw 10 Secondary element 5...

Страница 6: ...sing screws or stud bolts washers and self locking nuts M8 tightening torque 10 2 Nm Depending on the version threaded inserts M8 and or fixation eyelets are provided on the filter for this purpose Sl...

Страница 7: ...air filter to ejector Check for damage leaks Monthly and after repair work Cyclone block Check for signs of damage and clean According to conditions of use and type of contamination Plastic housing an...

Страница 8: ...irt gets into the clean air side of the filter Check all the parts for signs of damage and wear replace them as necessary IQORON series 10 12 and 14 Move the red clamping bar towards Unlock refer to F...

Страница 9: ...Fig 7 and mount the lid Fit the wire clamp fasteners in the slot in the flange on the housing and lock them 6 3 Maintenance of the secondary element The secondary element must be changed every 5th mai...

Страница 10: ...oreign bodies and dust deposits from the cyclone block and inside the housing by hand or by means of a brush for example Loosen stubborn dust deposits on the cyclone block by soaking in a PA6 compatib...

Страница 11: ...if necessary refer to Section 6 Incorrect maintenance Remove dust thoroughly complete maintenance in accordance with Section 6 Housing not sealed properly Remove dust thoroughly check main filter elem...

Страница 12: ...GF 30 Plastics recycling center Secondary element Filter paper Polyurethane foam Adhesive PA 6 Dispose of according to local regulations Housing lid PA 6 GF30 Plastics recycling center Housing with w...

Страница 13: ...MANN HUMMEL Industrial Filters 13 Notes MANN HUMMEL GMBH Gesch ftsbereich Industriefilter 67346 Speyer Germany Telephone 49 62 32 53 80 Fax 49 62 32 53 88 99 E mail if info mann hummel com Internet w...

Отзывы: