MANN+HUMMEL IQORON
MANN+HUMMEL Industrial Filters
10
Fig. 8
Secondary element
(Fig. illustrates size 7)
6.3.3
Installing the main filter element
(Refer to Section 6.2.3)
6.4
Maintenance of the cyclone block
Blocked cyclone cells (e.g. by blades of grass
sucked up) have a lower level of efficiency.
To ensure a long service life for the main filter
element, check the cyclone block regularly
and clean it as necessary.
Be careful not to damage the
cyclone cell.
Do not use any hard or sharp-
edged tools!
Unscrew the central bolt (Allen screw a/f 5,
Pos. 4).
Pull out the cyclone block fully.
Remove any foreign bodies and dust
deposits from the cyclone block and inside
the housing by hand or by means of a
brush, for example.
Loosen stubborn dust deposits on the
cyclone block by soaking in a PA6-
compatible cleaning agent and remove with
a water jet.
Blow the cyclone block dry to prevent new
dust accumulating again.
Slide the cyclone block in the housing.
Screw in the Allen screw with washer (Ma =
6 +/- 2 Nm).
Slide the inner housing section in the
cyclone block housing.
Screw in the hexagonal screw and washer
(Ma = 6 +/- 2 Nm).
7
Storing Filter Elements
Protect filter elements in storage from exposure to dust, moisture and damage.
It is preferable to keep them stored in their original packaging.
It is practical to keep at least one spare element in stock for each filter element used.
Seal
Frame
Handle