background image

MANN+HUMMEL IQORON 

 MANN+HUMMEL Industrial Filters 

 

 

 

 

 

 

         5 

 

 

 

 

 

 

Fig. 2 

IQORON size 10 (sizes 12 and 14 are comparable) 

 

Pos.  Name 

 

Pos.  Name 

Lid 

 

Connection for maintenance indicator/switch 

Main filter element 

 

Clean air connection 

Cyclone block 

 

Wire clamp fastener  

Allen screw 

 

10 

Secondary element  

Dust discharge connection 

 

11 

Filter frame with locking bar  

Housing 

 

 

 

 

 
 

 

10 

11 

Содержание IQORON 10

Страница 1: ...Version 0709 MANN HUMMEL IQORON 7 10 12 14 Installation and Maintenance Manual...

Страница 2: ...block 10 7 Storing Filter Elements 10 8 Troubleshooting 11 9 Disposing of Parts 12 1 Foreword This installation and maintenance manual serves to help you become familiar with the IQORON and its intend...

Страница 3: ...eyond this such as filtering aggressive combustible and or explosive materials is considered unintended use The manufacturer supplier is not considered liable for damage resulting from unintended use...

Страница 4: ...the filter must be serviced The secondary element Pos 10 protects the engine from penetration by dust during maintenance and to a certain extent during operation with a main filter element damaged th...

Страница 5: ...comparable Pos Name Pos Name 1 Lid 7 Connection for maintenance indicator switch 2 Main filter element 8 Clean air connection 3 Cyclone block 9 Wire clamp fastener 4 Allen screw 10 Secondary element 5...

Страница 6: ...sing screws or stud bolts washers and self locking nuts M8 tightening torque 10 2 Nm Depending on the version threaded inserts M8 and or fixation eyelets are provided on the filter for this purpose Sl...

Страница 7: ...air filter to ejector Check for damage leaks Monthly and after repair work Cyclone block Check for signs of damage and clean According to conditions of use and type of contamination Plastic housing an...

Страница 8: ...irt gets into the clean air side of the filter Check all the parts for signs of damage and wear replace them as necessary IQORON series 10 12 and 14 Move the red clamping bar towards Unlock refer to F...

Страница 9: ...Fig 7 and mount the lid Fit the wire clamp fasteners in the slot in the flange on the housing and lock them 6 3 Maintenance of the secondary element The secondary element must be changed every 5th mai...

Страница 10: ...oreign bodies and dust deposits from the cyclone block and inside the housing by hand or by means of a brush for example Loosen stubborn dust deposits on the cyclone block by soaking in a PA6 compatib...

Страница 11: ...if necessary refer to Section 6 Incorrect maintenance Remove dust thoroughly complete maintenance in accordance with Section 6 Housing not sealed properly Remove dust thoroughly check main filter elem...

Страница 12: ...GF 30 Plastics recycling center Secondary element Filter paper Polyurethane foam Adhesive PA 6 Dispose of according to local regulations Housing lid PA 6 GF30 Plastics recycling center Housing with w...

Страница 13: ...MANN HUMMEL Industrial Filters 13 Notes MANN HUMMEL GMBH Gesch ftsbereich Industriefilter 67346 Speyer Germany Telephone 49 62 32 53 80 Fax 49 62 32 53 88 99 E mail if info mann hummel com Internet w...