background image

WARRANTY

All Manley Laboratories  equipment  is covered by a limited warranty against defects in materials
and workmanship for a period of 90 days from date of purchase to the original purchaser only. A
further optional limited 5 year warranty is available to the original purchaser upon proper
registration of ownership within 30 days of date of first purchase.

Proper registration is made by filling out and returning to the factory the warranty card attached to
this general warranty statement, along with a copy of the original sales receipt as proof of the
original date of purchase. Only 1 card is issued with each unit, and the serial number is already
recorded on it.

If the warranty registration card has already been removed then this is not a new unit, and is
therefore not warranted by the factory. If you believe this to be a new unit then please contact the
factory with the details of purchase.

This warranty is provided by the dealer where the unit was purchased, and by Manley Laboratories,
Inc.   Under the terms of the warranty defective parts will be repaired or replaced without charge,
excepting the cost of tubes. No warranty is offered on tubes, unless:
1. a Manley Laboratories preamplifier is used with a Manley Laboratories  amplifier, and
2. the warranty registration card is filled out.

In such a case a 6 month warranty on tubes is available with the correct recording of the serial
number of the preamplifier on your warranty registration card.

If a Manley Laboratories  product fails to meet the above warranty, then the purchaser's sole
remedy shall be to return the product to Manley Laboratories, where the defect will be repaired
without charge for parts and labour. The product will then be returned via prepaid, insured freight,
method and carrier to be determined solely by Manley Laboratories. All returns to the factory must
be in the original packing, (new packing will be supplied for no charge if needed), accompanied by
a written description of the defect, and must be shipped to Manley Laboratories via insured freight
at the customer's own expense. Charges for unauthorized service and transportation costs are not
reimbursable under this warranty, and all warrantees, express or implied, become null and void
where the product has been damaged by misuse, accident, neglect, modification, tampering or
unauthorized alteration by anyone other than Manley Laboratories.

 The warrantor assumes no liability for property damage or any other incidental or consequental
damage whatsoever which may result from failure of this product. Any and all warrantees of
merchantability and fitness implied by law are limited to the duration of the expressed warranty.
All warrantees apply only to Manley Laboratories products purchased and used in the USA.

Some states do not allow limitations on how long an implied warranty lasts, so the above
limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental
or consequential damges, so the above exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights which vary from
state to state.

Содержание Enhanced Pultec Mid Frequency Equalizer

Страница 1: ...MANLEY LABORATORIES INC OWNER S MANUAL ENHANCED MID FREQUENCY PULTEC EQUALIZER...

Страница 2: ...ON 3 EQ HINTS 4 FRONT PANEL 5 REAR PANEL 6 MAINS CONNECTIONS 7 TECH NOTES 8 TROUBLESHOOTING 9 10 CURVES 11 WARRANTY 13 WARRANTY REGISTRATION 14 APPENDIX WIRING YOUR OWN CABLES TEMPLATE FOR STORING SET...

Страница 3: ...he distortion as such The older transformers suffered from wide band distortion and losses inthehighs Thisisrarelywanted Modernhighqualitytransformersaremuchbetterinthehighsandgenerally much lower dis...

Страница 4: ...lexible for mastering Many of the most recognised engineers suggest cutting rather than boosting According to them it sounds like less phase shift and resonance They would start by dipping a little in...

Страница 5: ...ful hard sounds while the 5 or 7 kHz are often used to compensate for microphone diaphragm resonances E MID FREQUENCY DIP peak Provides continuously variable CUT from 0 to 10 or 12 dB to the selected...

Страница 6: ...inserted Tip Signal Sleeve Ground Ring unused Use either output but not both F GAIN SET PRESET This control adjusts the feedback over the line amplifier It is preset for unity gain however additional...

Страница 7: ...ire which is coloured BROWN must be connected to the terminal in the plug which is marked by the letter L or coloured RED This unit like most pro gear is designed for third pin AC mains ground See the...

Страница 8: ...it Replacement tubes can be obtained from Manley Laboratories However if you re stuck in a pinch the following tubes are approved substitutes for this unit For the 5814 12AU7WA ECC82 exact substitutes...

Страница 9: ...BYPASS The signal goes through the tube stage in Bypass Let s assume the wiring has been checked twice There is about a 98 chance it is a tube If it were solid state you would generally send it back...

Страница 10: ...we know of David showed us that they have less coloration than Penny Giles faders on bigconsoles Unfortunatelythey feel loose Wecouldusecheapunsealedpotslikemostothercompaniesbutthenwewould not feel...

Страница 11: ......

Страница 12: ...015 Noise Floor Gain set to minimum 80 dB Wideband Signal to Noise 126 dB typical Maximum Gain via trim on back 5 dB to 5 dB Maximum EQ Boost 12 dB low mids 10 dB high mids Maximum EQ Cut 12 dB 10 db...

Страница 13: ...rwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutcharge...

Страница 14: ..._ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL MANLEY MID FREQUENCY PULTEC EQ SERIAL No ____________ PURCHASE DATE ______________ SUPPLIER ______...

Страница 15: ......

Отзывы: