background image

 

Your REFERENCE MICROPHONE Power Supply has been factory set to the 

correct mains voltage for your country. The voltage setting is marked on the serial badge, 

located on the underside of the power suppy. Check that this complies with your local 

supply. 

 

Export units for certain markets have a moulded mains plug fitted to comply 

with local requirements. If your unit does not have a plug fitted the coloured wires should 

be connected to the appropriate plug terminals in accordance with the following code:

 GREEN/YELLOW 

 EARTH

 BLUE 

  NEUTRAL

 BROWN 

  LIVE

 

As the colours of the wires in the mains lead may not correspond with the 

coloured marking identifying the terminals in your plug proceed as follows:

The wire which is coloured GREEN/YELLOW must be connected to the terminal in the 

plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or 

GREEN and YELLOW.

The wire which is coloured BLUE must be connected to the terminal in the plug which is 

marked by the letter N or coloured BLACK.

The wire which is coloured BROWN must be connected to the terminal in the plug which 

is marked by the letter L or coloured RED.

DO NOT CONNECT/SWITCH ON THE MAINS SUPPLY UNTIL ALL OTHER 

CONNECTIONS HAVE BEEN MADE.

Note: Units are purpose built for original destination country’s mains voltage: 100V, 

120V, or 220-240VAC as indicated on the serial number badge. Power transformer 

can be rewired for another country’s mains voltage via internal jumpers and fuse 

change. See page 11 for details.

100V and 120V operation: 250mA SLO-BLO fuse.

220-240V operation: 125mA SLO-BLO fuse.

***Fuses for ALL VOLTAGES are 5x20mm GDC packaged fuses.***

MAINS CONNECTIONS

Waste Electrical and Electronic Equipment (WEEE)
Information for customers:

The European Parliament and the Council of the European Union have issued the Waste Electrical and Electronic 

Equipment Directive. The purpose of the Directive is the prevention of waste of electrical and electronic equip-

ment, and to promote the reuse and recycling and other forms of recovery of such waste. As such the Directive 

concerns producers, distributors and consumers.
The WEEE directive requires that both manufacturers and end-consumers dispose of electrical and electronic 

equipment and parts in an environmentally safe manner, and that equipment and waste are reused or recov-

ered for their materials or energy. Electrical and electronic equipment and parts must not be disposed of with 

normal household wastage; all electrical and electronic equipment and parts must be collected and disposed of 

separately.
Products and equipment which must be collected for reuse, recycling and 

other forms of recovery are marked with the following pictogram:

Small products may not always be marked with this pictogram in which case this is present in the instructions for 

use, on the guarantee certificate and printed on the packaging.
When disposing of electrical and electronic equipment by use of the collection systems available in your country, 

you protect the environment, human health and contribute to the prudent and rational use of natural resources. 

Collecting electrical and electronic equipment and waste prevents the potential contamination of nature with the 

hazardous substances which may be present in electrical and electronic products and equipment.
Your MANLEY or LANGEVIN retailer will assist with and advise you of the correct way of disposal in your 

country.

7

Содержание Cardioid

Страница 1: ...MANLEY REFERENCE MICROPHONES OWNER S MANUAL Reference Cardioid Reference Mono Gold Reference Stereo Gold rev9 2 11cd...

Страница 2: ...CONTENTS SECTION PAGE INTRODUCTION 3 POWER SUPPLY 4 MICROPHONE CONTROLS 5 GENERAL NOTES 6 MAINS CONNECTIONS 7 TROUBLESHOOTING 8 STEREO GOLD ADDENDUM 9 SPECIFICATIONS 10 VOLTAGE CONVERSION 11...

Страница 3: ...nd are mounted on Teflon insulator rings The gold diaphragm film comes from Germany and is tensioned using proprietary techniques which ensures capsule to capsule constancy We have found the 5 micron...

Страница 4: ...of having two complete microphone systems in one housing the stereo mic has a dedicated 4 pin power cable that goes to the base of the mic Audio is carried out from a single jack that is then split i...

Страница 5: ...cal situation where a few inches of distance can make or break a take We also chose to allow the frequency response of the Reference Mics to extend below 20 Hz Some mics seem to have a low frequency r...

Страница 6: ...ower supply to the wall outlet and turn on the supply Let the mic warm up for at least 5 minutes before using If any of the connections at the base of the microphone become loose over time they can be...

Страница 7: ...S are 5x20mm GDC packaged fuses MAINS CONNECTIONS Waste Electrical and Electronic Equipment WEEE Information for customers The European Parliament and the Council of the European Union have issued the...

Страница 8: ...most likely a ground loop Try a 3 pin to 2 pin AC adaptor about a dollar at a hardware store We do not recommend breaking off the power cable s grounding pin BUZZ This is most likely a faulty ground s...

Страница 9: ...the included cable ensure each of the pins are oriented correctly The cable should screw on easily if the tab is lined up within the connector MIC BASE 6 pin audio connector PSU INCLUDED Y CABLE XLR...

Страница 10: ...UBE DEPENDENT BODY 24 KARAT GOLD OVER MACHINED BRASS REFERENCE CARDIOID CAPSULE TYPE CENTER FIXED LG DIAPHRAGM CAPACITOR POLAR PATTERN FIXED CARDIOID DIAPHRAGM SIZE 1 INCH 1 25 INCH OVERALL DIAPHRAGM...

Страница 11: ...ocated on PCB0718B and the accompanying diagram printed on the PCB itself 4 For 100V solder jumpers W2 W3 W6 For 120V solder jumpers W1 W4 W6 For 220 230V solder jumpers W2 W5 For 240V solder jumpers...

Отзывы: