Содержание Cardioid

Страница 1: ...MANLEY REFERENCE MICROPHONES OWNER S MANUAL Reference Cardioid Reference Mono Gold Reference Stereo Gold rev9 2 11cd...

Страница 2: ...CONTENTS SECTION PAGE INTRODUCTION 3 POWER SUPPLY 4 MICROPHONE CONTROLS 5 GENERAL NOTES 6 MAINS CONNECTIONS 7 TROUBLESHOOTING 8 STEREO GOLD ADDENDUM 9 SPECIFICATIONS 10 VOLTAGE CONVERSION 11...

Страница 3: ...nd are mounted on Teflon insulator rings The gold diaphragm film comes from Germany and is tensioned using proprietary techniques which ensures capsule to capsule constancy We have found the 5 micron...

Страница 4: ...of having two complete microphone systems in one housing the stereo mic has a dedicated 4 pin power cable that goes to the base of the mic Audio is carried out from a single jack that is then split i...

Страница 5: ...cal situation where a few inches of distance can make or break a take We also chose to allow the frequency response of the Reference Mics to extend below 20 Hz Some mics seem to have a low frequency r...

Страница 6: ...ower supply to the wall outlet and turn on the supply Let the mic warm up for at least 5 minutes before using If any of the connections at the base of the microphone become loose over time they can be...

Страница 7: ...S are 5x20mm GDC packaged fuses MAINS CONNECTIONS Waste Electrical and Electronic Equipment WEEE Information for customers The European Parliament and the Council of the European Union have issued the...

Страница 8: ...most likely a ground loop Try a 3 pin to 2 pin AC adaptor about a dollar at a hardware store We do not recommend breaking off the power cable s grounding pin BUZZ This is most likely a faulty ground s...

Страница 9: ...the included cable ensure each of the pins are oriented correctly The cable should screw on easily if the tab is lined up within the connector MIC BASE 6 pin audio connector PSU INCLUDED Y CABLE XLR...

Страница 10: ...UBE DEPENDENT BODY 24 KARAT GOLD OVER MACHINED BRASS REFERENCE CARDIOID CAPSULE TYPE CENTER FIXED LG DIAPHRAGM CAPACITOR POLAR PATTERN FIXED CARDIOID DIAPHRAGM SIZE 1 INCH 1 25 INCH OVERALL DIAPHRAGM...

Страница 11: ...ocated on PCB0718B and the accompanying diagram printed on the PCB itself 4 For 100V solder jumpers W2 W3 W6 For 120V solder jumpers W1 W4 W6 For 220 230V solder jumpers W2 W5 For 240V solder jumpers...