GENERAL NOTES 

CONNECTIONS 

MONO REFERENCE GOLD & REFERENCE CARDIOID MODELS - connect 

6-pin cable (supplied with mic) between PSU and mic. Audio comes from 

separate 3 pin XLR on the PSU.

STEREO REFERENCE GOLD MODEL - carefully connect the 4 pin power 

cables to the mic and power supply. Line up the groove and ridge of these 

connectors to prevent accidental damage. Next connect a known good mic cable 

to the power supply, and you’re ready to record.

 

If possible, use a short cable and a high quality microphone preamplifier (with 

the phantom power turned off) located near the mic. This is usually the best 

for audio quality. Try to avoid running the mic signal thru a patch bay or extra 

connectors and wires. Attach the mic securely to a good mic stand and and lay 

the cables so that people cannot trip over the cable or topple the stand. Connect 

the power supply to the wall outlet and turn on the supply. Let the mic warm up 

for at least 5 minutes before using.

If any of the connections at the base of the microphone become loose over time, 

they can be easily tightened with a 1/16” allen key.

WATER & MOISTURE 

As with any electrical equipment, this unit should not be used near water or 

moisture. In rare situations moisture from breath may temporarily cause loss of 

output from condenser mics. Do not use a blower or heat to accelerate drying. 

Extreme humidity may comprimise the performance of some high value ( 500 

M

Ω

 and 200 M

Ω

 ) resistors in the circuit. If liquid enters the unit, it must be 

immediately returned to your dealer for servicing. 

SERVICING 

The user should not attempt to service this unit beyond that described in the 

owner’s manual.  Refer all servicing to Manley Laboratories.

WARNING! 

TO PREVENT THE RISK OF ELECTRIC SHOCK, 

DO NOT OPEN THE POWER SUPPLY CABINET OR 

REMOVE THE SHELL FROM THE MICROPHONE.

-------- HIGH VOLTAGES --------

REFER SERVICING TO QUALIFIED PERSONEL

www.manley.com/service.php  

6

Содержание Cardioid

Страница 1: ...MANLEY REFERENCE MICROPHONES OWNER S MANUAL Reference Cardioid Reference Mono Gold Reference Stereo Gold rev9 2 11cd...

Страница 2: ...CONTENTS SECTION PAGE INTRODUCTION 3 POWER SUPPLY 4 MICROPHONE CONTROLS 5 GENERAL NOTES 6 MAINS CONNECTIONS 7 TROUBLESHOOTING 8 STEREO GOLD ADDENDUM 9 SPECIFICATIONS 10 VOLTAGE CONVERSION 11...

Страница 3: ...nd are mounted on Teflon insulator rings The gold diaphragm film comes from Germany and is tensioned using proprietary techniques which ensures capsule to capsule constancy We have found the 5 micron...

Страница 4: ...of having two complete microphone systems in one housing the stereo mic has a dedicated 4 pin power cable that goes to the base of the mic Audio is carried out from a single jack that is then split i...

Страница 5: ...cal situation where a few inches of distance can make or break a take We also chose to allow the frequency response of the Reference Mics to extend below 20 Hz Some mics seem to have a low frequency r...

Страница 6: ...ower supply to the wall outlet and turn on the supply Let the mic warm up for at least 5 minutes before using If any of the connections at the base of the microphone become loose over time they can be...

Страница 7: ...S are 5x20mm GDC packaged fuses MAINS CONNECTIONS Waste Electrical and Electronic Equipment WEEE Information for customers The European Parliament and the Council of the European Union have issued the...

Страница 8: ...most likely a ground loop Try a 3 pin to 2 pin AC adaptor about a dollar at a hardware store We do not recommend breaking off the power cable s grounding pin BUZZ This is most likely a faulty ground s...

Страница 9: ...the included cable ensure each of the pins are oriented correctly The cable should screw on easily if the tab is lined up within the connector MIC BASE 6 pin audio connector PSU INCLUDED Y CABLE XLR...

Страница 10: ...UBE DEPENDENT BODY 24 KARAT GOLD OVER MACHINED BRASS REFERENCE CARDIOID CAPSULE TYPE CENTER FIXED LG DIAPHRAGM CAPACITOR POLAR PATTERN FIXED CARDIOID DIAPHRAGM SIZE 1 INCH 1 25 INCH OVERALL DIAPHRAGM...

Страница 11: ...ocated on PCB0718B and the accompanying diagram printed on the PCB itself 4 For 100V solder jumpers W2 W3 W6 For 120V solder jumpers W1 W4 W6 For 220 230V solder jumpers W2 W5 For 240V solder jumpers...

Отзывы: