SPECIFICATIONS

Vacuum Tubes:

2 x KT-90 or 6550 (or good KT-88)

, 1 x 5751, 1 x 7044

Output Power

120 Watts tetrode, 65 triode

Frequency Response, +/- 1 dB

20 Hz - 50 KHz

Input Sensitivity

1 Volt nominal

Input Impedance

100 KOhm

Load Impedance

5 Ohm.  Factory preset for 5 Ohm

S/N Ratio  @100W

-100 dB

Power Consumption

120 Watts

Quiescent

360 Watts

Full Power

Mains Fuse

100, 110, 120V

4 A   (Slo-Blo)

220, 240 V

2 A   (Slo-Blo)

Dimensions

W=12, D=10, H=6  inches
W=19, D=12, H=6 (panel=3.5) (rack mount version)

Shipping Weight

27  lbs (each)

Содержание 120 Watt Monoblock Amplifier

Страница 1: ...LABORATORIES INC OWNER SMANUAL MANLEY 120 WATT MONOBLOCK AMPLIFIER Manley Laboratories Inc 13880 Magnolia Ave Chino CA 91710 tel 909 627 4256 fax 909 628 2482 emanley manleylabs com http www manleyla...

Страница 2: ...CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 BIAS PROCEDURES 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10 SECTION PAGE...

Страница 3: ...flow of air can flow throughout the ventilation openings We also recommend that the amplifier and preamplifier be placed at least 10 inches apart Do not place amplifiers directly on high pile carpet...

Страница 4: ...E NEUTRAL terminal BROWN LIVE terminal As the colors of the wires in the mains lead may not correspond with the colored marking identifying the terminals in your plug proceed as follows The wire which...

Страница 5: ...Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the posts or you may breaak the connection inside the amplifier 4 Insure that the mains switch on the front panel is...

Страница 6: ...Also you MUST leave your loadspeakers connected as these provide an ideal load on the output Never operate your amplifiers without a suitable load or speakers attatched It is recommended that you leav...

Страница 7: ...ECIAL NOTE The Manley 120 Watt Monoblocks are equipped with a voltage change over switch located under the bottom cover Insure that this switch is set at 110 if your mains voltage is 100 110 120 or 12...

Страница 8: ...KHz Input Sensitivity 1 Volt nominal Input Impedance 100 KOhm Load Impedance 5 Ohm Factory preset for 5 Ohm S N Ratio 100W 100 dB Power Consumption 120 Watts Quiescent 360 Watts Full Power Mains Fuse...

Страница 9: ...atories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired without charge for parts and labor The product will t...

Страница 10: ...______________ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL ____________________ SE...

Отзывы: