background image

OPERATIONAL  NOTES

SWITCHING ON
The power switch is located on the lower left hand corner of the front panel.  Push the top of the
rocker switch (1) to turn on the amplifier and the bottom of the rocker to turn off the amplifier.  The
LED on the right side of the front panel will illuminate indicating that the amplifier is operating. Do
not turn on and off the amplifier in rapid succession.

RUNNING
It is not recommended that you leave your amplifier permanently switched on.  This only wastes
electricity and tube life.  Your amplifier has solid state rectification and reaches peak operating
condition in approximately 30 minutes.

TUBE LIFE
As with all tubes, their quality degrades with age.  This is due to cathode emission, a natural process
found in all tubes.  We recommend that you have your amplifier checked every 3-4 years, depending
on usage, sometimes the amplifier will require re-tubing after this time has elapsed, although we
have many cases of extreme long life recorded-- 40,000 hours and still counting!.

SPECIAL NOTE
The Manley 120 Watt Monoblocks are equipped with a voltage change-over switch located under
the bottom cover.  Insure that this switch is set at 110 if your mains voltage is 100,110,120, or 127
Volts.  Set this switch to 220 if your mains voltage is 220, 227, or 240 Volts.

Changing the light bulb:
The lamp which back-lights the Manley insert on the faceplate is a fuse-lamp style lamp. Should it
burn out, turn off and unplug the amplifer from the mains first. Then remove the bottom cover.
Carefully pry out the old lamp from its clips and replace with one of the same type. Although it
looks like a fuse, it is really a light bulb!! Don't put a fuse in there!!

The fuse lamp is 1 1/4" x 1/4" 8Volts, 300mA.

Fuses:
Always replace with same type and rating. Should the B+ fuse blow (the fuse nearer to the output
binding posts) this usually indicates a tube has blown. One should visually inspect the pcb to look
for any burnt resistors a blown tube may have taken out. Also a good test is to measure the resistance
of each catode resistor. This is done in a similar fashion to checking the bias, except do this test with
the amplifier turned OFF, and set your meter for Ohms. Each cathode resistor should measure 10
ohms.

Содержание 120 Watt Monoblock Amplifier

Страница 1: ...LABORATORIES INC OWNER SMANUAL MANLEY 120 WATT MONOBLOCK AMPLIFIER Manley Laboratories Inc 13880 Magnolia Ave Chino CA 91710 tel 909 627 4256 fax 909 628 2482 emanley manleylabs com http www manleyla...

Страница 2: ...CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 BIAS PROCEDURES 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10 SECTION PAGE...

Страница 3: ...flow of air can flow throughout the ventilation openings We also recommend that the amplifier and preamplifier be placed at least 10 inches apart Do not place amplifiers directly on high pile carpet...

Страница 4: ...E NEUTRAL terminal BROWN LIVE terminal As the colors of the wires in the mains lead may not correspond with the colored marking identifying the terminals in your plug proceed as follows The wire which...

Страница 5: ...Tighten the binding posts by hand If you use a nut driver 3 8 do not over tighten the posts or you may breaak the connection inside the amplifier 4 Insure that the mains switch on the front panel is...

Страница 6: ...Also you MUST leave your loadspeakers connected as these provide an ideal load on the output Never operate your amplifiers without a suitable load or speakers attatched It is recommended that you leav...

Страница 7: ...ECIAL NOTE The Manley 120 Watt Monoblocks are equipped with a voltage change over switch located under the bottom cover Insure that this switch is set at 110 if your mains voltage is 100 110 120 or 12...

Страница 8: ...KHz Input Sensitivity 1 Volt nominal Input Impedance 100 KOhm Load Impedance 5 Ohm Factory preset for 5 Ohm S N Ratio 100W 100 dB Power Consumption 120 Watts Quiescent 360 Watts Full Power Mains Fuse...

Страница 9: ...atories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired without charge for parts and labor The product will t...

Страница 10: ...______________ SERIAL No ______________________ PURCHASE DATE ______________ SUPPLIER ______________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL ____________________ SE...

Отзывы: