Section 7
. Refrigeration System
Part Number 80-1558-3
7-7
3.
Extremely Thin at Evaporator Inlet
There is no ice, or a considerable lack of ice formation at
the inlet of the evaporator. Examples: The ice at the
outlet of the evaporator reaches 1/8" to initiate a harvest,
but there is no ice formation at all at the inlet of the
evaporator.
Possible causes: Insufficient water flow, flooding TXV,
etc.
Figure 7-4. Extremely Thin Ice Formation at
Evaporator Inlet
4.
Spotty Ice Formation
There are small sections on the evaporator where there
is no ice formation. This could be a single corner, or a
single spot in the middle of the evaporator. This is
generally caused by loss of heat transfer from the tubing
on the back side of the evaporator.
Figure 7-5. Spotty Ice Formation
5.
No Ice Formation
The ice machine operates for an extended period, but
there is no ice formation at all on the evaporator.
Possible causes: Water inlet valve, water pump, starving
expansion valve, low refrigerant charge, compressor,
etc.
Figure 7-6. No Ice Formation
OUTLET
INLET
ICE
OUTLET
INLET
ICE
OUTLET
INLET
Содержание S0850M
Страница 24: ...Ice Machine Operation Section 3 3 6 Part Number 80 1558 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Electrical System Section 6 6 28 Part Number 80 1558 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ... Refrigeration System Section 7 7 26 Part Number 80 1558 3 Figure 7 10 Using Pinch Off Tool SV1406 ...
Страница 97: ...Section 7 Refrigeration System Part Number 80 1558 3 7 31 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ... Refrigeration System Section 7 7 32 Part Number 80 1558 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 99: ......