Section 7
Refrigeration System
Part Number 80-1480-3
7-37
S600 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
S600 SERIES
Remote
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
7.6-9.0
7.9-9.4
8.6-10.1
1-2.5
80/26.7
7.8-9.2
8.1-9.5
8.8-10.3
90/32.2
7.9-9.4
8.2-9.7
8.8-10.3
100/37.8
8.1-9.5
8.4-9.9
9.1-10.7
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
650
630
590
80/26.7
640
620
580
90/32.2
630
610
580
100/37.8
620
600
560
Based on average ice slab weight of 4.12 - 4.75lb
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
59/15.0
70/21.1
90/32.2
Gal / per
100 lbs of ice
110
170
870
Water regulating valve set to maintain 2340 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
36-26
140-190
65-95
70/21.1
225-235
36-26
140-190
65-95
80/26.7
225-245
40-28
150-195
70-100
90/32.2
230-255
40-29
160-200
70-100
100/37.8
230-260
40-30
170-205
75-105
110/43.3
230-260
40-30
180-210
80-110
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
7.9-9.4
8.8-10.3
9.3-10.9
1-2.5
80/26.7
7.9-94
8.9-10.5-
9.5-11.2
90/32.2
8.1-9.5
8.9-10.5
9.7-11.4
100/37.8
8.8-10.3
9.7-11.4
10.4-12.2
110/43.3
9.7-11.4
10.6-12.5
11.4-13.4
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
630
580
550
80/26.7
630
570
530
90/32.2
620
570
540
100/37.8
580
530
500
110/43.3
530
490
460
Based on average ice slab weight of 4.12 - 4.75 lb
Ratings with JC495 condenser, dice or half dice cubes
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
210-240
40-29
130-190
62-80
70/21.1
225-250
50-30
130-200
75-95
80/26.7
245-275
52-31
130-200
75-100
90/32.2
245-285
52-32
135-200
80-100
100/37.8
260-315
55-32
140-200
80-100
110/43.3
290-365
60-34
170-200
85-100
Suction pressure drops gradually throughout the freeze cycle
Содержание S model
Страница 3: ......
Страница 10: ...Table of Contents continued 6 Part No 80 1480 3 ...
Страница 36: ...Installation Instructions Section 2 2 22 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...Ice Machine Operation Section 3 3 6 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 56: ...Maintenance Section 4 4 14 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 59: ...Section 5 Before Calling For Service Part Number 80 1480 3 5 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...Before Calling For Service Section 5 5 4 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 70: ...Electrical System Section 6 6 10 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Electrical System Section 6 6 46 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 162: ...Refrigeration System Section 7 7 56 Part Number 80 1480 3 Figure 7 17 Using Pinch Off Tool SV1406 ...
Страница 168: ...Refrigeration System Section 7 7 62 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...