Maintenance
Section 4
4-12
Part Number 80-1480-3
Water Inlet Valve
The water inlet valve normally does not require removal
for cleaning. Refer to Section 5 for a list of causes for
“No Water Entering Water Trough” or “Water Overflows
Water Trough.
1. When the ice machine is off, the water inlet valve
must completely stop water flow into the machine.
2. When the ice machine is on, the water inlet valve
must allow the proper water flow through it. Set the
toggle switch to ON. Watch for water flow into the ice
machine. If the water flow is slow or only trickles into
the ice machine, refer to Section 5.
Follow the procedure below to remove the water inlet
valve.
1. Remove the 1/4” hex head screws.
2. Remove, clean, and install the filter screen.
Removing the Front Panels
NOTE: The front panels do not normally have to be
removed. If needed perform the following procedure.
1. Loosen screws. Do not remove they are retained by
o-rings to prevent loss.
2.
30 Inch and 48 Inch Models Only
: To remove right
front door lift up and remove (22 inch machines have
a single door, proceed to step 3).
Door Removal
3. Open left front door to 45 degrees.
4. Support with left hand, depress top pin, tilt top of
door forward and lift out of bottom pin to remove.
!
Warning
Disconnect the electric power to the ice machine
and dispenser at the electric service switch box and
turn off the water supply before proceeding.
SV1622
FILTER
ACCESS
SCREWS
WATER
INLET
VALVE
3
2
5
Содержание S model
Страница 3: ......
Страница 10: ...Table of Contents continued 6 Part No 80 1480 3 ...
Страница 36: ...Installation Instructions Section 2 2 22 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...Ice Machine Operation Section 3 3 6 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 56: ...Maintenance Section 4 4 14 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 59: ...Section 5 Before Calling For Service Part Number 80 1480 3 5 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 60: ...Before Calling For Service Section 5 5 4 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 70: ...Electrical System Section 6 6 10 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 106: ...Electrical System Section 6 6 46 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 162: ...Refrigeration System Section 7 7 56 Part Number 80 1480 3 Figure 7 17 Using Pinch Off Tool SV1406 ...
Страница 168: ...Refrigeration System Section 7 7 62 Part Number 80 1480 3 THIS PAGE INTENTIONALLY LEFT BLANK ...