–61–
Problem: Water Will Not Run into the Sump Trough
During the Freeze Cycle
Step 1.
Verify water is supplied to the ice machine,
and then start a new Freeze sequence by moving the
ICE/OFF/CLEAN toggle switch to OFF, then back to
ICE.
Step 2.
Wait until the Freeze cycle starts
(approximately 45 seconds – the Freeze cycle starts
when the compressor energizes), and then refer to the
chart.
Important
This restart must be done prior to performing
diagnostic procedures. This assures the ice machine
is not in a Freeze cycle water inlet valve safety shut-
off mode. You must complete the entire diagnostic
procedure within 6 minutes of starting.
Step 2. Checking for Normal Operation
Is Water
Flowing
into the
Water
Trough?
The
Water
Level
Light Is:
The Water
Inlet Valve
Solenoid
Coil Is:
Cause
Yes
Off
Energized
This is
normal
operation.
Do not
change any
parts.
No
On or
Off
Energized
or
De-energized
Proceed to
step 3.
Содержание Marine Q 1000
Страница 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Страница 2: ......
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Страница 177: ......
Страница 178: ......