SUCTION PRESSURE HIGH CHECKLIST
Problem
•
Cause
Improper Installation
•
Refer to “Installation/Visual Inspection Checklist”
Discharge Pressure
•
Discharge pressure is too high and is affecting low
side – refer to “Freeze Cycle Discharge Pressure
High Checklist”
Improper Refrigerant Charge
•
Overcharged
•
Wrong type of refrigerant
Other
•
Non-Manitowoc components in system
•
HPR solenoid leaking
•
Harvest valve leaking
•
TXV flooding (check bulb mounting)
•
Defective compressor