Refrigeration System
Safety Limit #2
Harvest time exceeds 3.5 minutes for 3 consecutive harvest cycles.
Possible Cause
Check/Correct
Improper installation
•
See “Installation/Visual Inspection Checklist” on page 7-10
Water system
•
Water area (evaporator) dirty
•
Dirty/defective water dump valve
•
Vent tube not installed on water outlet drain
•
Water freezing behind evaporator
•
Plastic extrusions and gaskets not securely mounted to the evaporator
•
Low water pressure (20 psi min.)
•
Loss of water from sump area
•
Clogged water distribution tube
•
Dirty/defective water fill valve
•
Defective water pump
Electrical system
•
Ice thickness probe out of adjustment
•
Ice thickness probe dirty
•
Bin switch defective
•
Premature harvest
Refrigeration system
•
Non-Manitowoc components
•
Water regulating valve dirty/defective
•
Improper refrigerant charge
•
Defective hot gas valve
•
TXV flooding (check bulb mounting)
SAFETY LIMIT NOTES
•
Because there are many possible external problems, do not limit your diagnosis to only the items listed in
this chart.
•
A continuous run of 100 harvests automatically erases the safety limit code.
•
The control board will store and indicate only one safety limit – the last one exceeded.
•
If the toggle switch is moved to the OFF position and then back to the ICE position prior to reaching the
100-harvest point, the last safety limit exceeded will be indicated.
•
If the harvest light did not flash prior to the ice machine restarting, then the ice machine did not stop
because it exceeded a safety limit.