![Manitowoc Marine Q 1000 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-manual_701043010.webp)
6
Electrical System
Harvest Sequence
5. WATER PURGE
The water pump continues to run, and
the water dump valve energizes for 45
seconds to purge the water in the sump
trough. The water fill valve energizes
(turns on) and de-energizes (turns off)
strictly by time. The water fill valve
energizes for the last 15 seconds of the
45-second water purge. The water
purge
*OVERLOAD
FAN CYCLE CONTROL
BIN SWITCH
TB35
TB33
(52)
(51)
(48)
CONTACTOR
CONTACTS
L1
(42)
(66)
(64)
ICE THICKNESS PROBE
WATER LEVEL PROBE
NOT USED
TB35
HIGH PRES
CUTOUT
TB32
L1
(55)
SV1646-5
RUN CAPACITOR
RUN CAPACITOR**
C
S
R
TB34
(53)
(47)
(85)
(86)
COMPRESSOR
FAN MOTOR
(AIR COOLED ONLY)
R
R
(45)
(46)
(50)
PTCR
BIN SWITCH LIGHT
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
CLEAN LIGHT
WATER LEVEL
(49)
(63)
(62)
(66)
(65)
(69)
ICE
OFF
CLEAN
(67)
(68)
1F
1C
LOW D.C.
VOLTAGE
PLUG
(62)
1G
TOGGLE SWITCH
68
67
69
66
62
VIEW FOR WIRING
INTERNAL WORKING
VIEW
TB37
(74)
(59)
(73)
(56)
CONTACTOR
COIL
TERMINATES AT
PIN CONNECTION
TB30
TB30
TB30
TB30
L2 (N)
SEE SERIAL PLATE FOR VOLTAGE
(58)
FUSE (7A)
TRANS.
2
4
1
3
5
(61)
(60)
TB31
(76)
(98)
(57)
(99)
(75)
HOT GAS
SOLENOID
DUMP
SOLENOID
(81)
WATER
PUMP
(77)
(80)
(21)
WATER
VALVE
(22)
TB30
TB30
must be at the factory setting of
45 seconds for the fill valve to
energize during the last 15 seconds of
the Water Purge. If set at less than 45
seconds, the water fill valve does not
energize during the water purge.
After the 45 second water purge, the
water fill valve, water pump and dump
valve de-energize. (Refer to "Water
Purge Adjustment for details.) The hot
gas valve also opens at the beginning
of the water purge to divert hot
refrigerant gas into the evaporator.
Self-Contained Models
5. Water Purge (45 Seconds)
Toggle Switch
ICE
Bin Switch
Closed
Control Board Relays
#1
Water Pump
Closed / ON
#2
Water Fill Valve
Cycles OFF then ON
#3
Hot Gas Solenoid
Closed / ON
#4
Water Dump Valve
Closed / ON
#5
Contactor Coil
Closed / ON
Compressor
ON
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out
Closed
Main Fuse (On Control Board)
Closed
Содержание Marine Q 1000
Страница 60: ...56 Refrigeration System Section 7 ...
Страница 61: ......