Low Converter Out Pressure.
1.
Low mainline pressure.
2.
Converter internal leakage.
3.
Converter relief valve faulty.
1.
See fault “Low Mainline Pressure.”
2.
Check and replace the torque
converter.
3.
Check and replace the relief valve.
Low Pump Flow.
1.
Low oil level.
2.
Blocked suction strainer.
1.
Add oil to transmission.
2.
Clean suction strainer.
High Converter Out Pressure.
1.
Oil cooler/lines blockage.
1.
Clean cooler, remove blockage.
Low Lubrication Pressure.
1.
Low mainline pressure.
2.
Oil cooler/lines blockage.
3.
Ruptured lubrication lines.
4.
Converter internal leakage.
5.
Converter relief valve faulty.
1.
See fault “Low Mainline Pressure.”
2.
Clean cooler, remove blockage.
3.
Repair line.
4.
Check and replace the torque
converter.
5.
Check, repair or replace the relief
valve.
Overheating.
1.
Low oil level.
2.
High oil level.
3.
Trapped or kinked hoses in cooler
system.
4.
Low converter out pressure relief
valve.
5.
Oil cooler blockage.
6.
Operating in wrong gear ranges.
7.
Engine cooling system
overheating.
8.
Foaming oil.
9.
Clutch pistons sticking on return
stroke.
10.
Passages on front housing pump
mounting face are the wrong
depth (indicated with an
excessively low pressure and flow
on the converter out cooling line).
11.
Leakage across pump mounting
face and front case.
1.
Add oil to transmission.
2.
Drain oil to correct level.
3.
Repair or replace hoses.
4.
Repair or replace the torque
converter and flow rate.
5.
Clean the oil cooler.
6.
Select correct gears to suit
working conditions.
7.
Find and repair engine cooling
problems.
8.
See fault “Low Mainline Pressure.”
9.
Check and repair clutch piston(s)
and seal(s).
10.
Replace front housing (or repair
existing housing).
11.
Check for damaged surface on
both components and loose pump
mounting bolts.
Problem
Possible Cause
Remedy
a0442
FIGURE 7-8
Reference Only
Содержание Grove YB5515-2
Страница 1: ...Shuttlelift CD5515 2 Grove YB5515 2 Service Maintenance Manual R e f e r e n c e O n l y ...
Страница 2: ...This Page Blank R e f e r e n c e O n l y ...
Страница 12: ...TABLE OF CONTENTS CD5515 2 YB5515 2 SERVICE MANUAL TOC 8 This Page Blank R e f e r e n c e O n l y ...
Страница 292: ...R e f e r e n c e O n l y ...
Страница 293: ...R e f e r e n c e O n l y ...