2-33
GROVE
GRT9165 SERVICE MANUAL
HYDRAULIC SYSTEM
2
Published 10-01-2020 Control # 699-00
Main Directional Control Valve
The main directional control valve (Figure 2-14) is located on
the right side of the superstructure (1, Figure 2-13). The
main directional valve controls the lift, telescope, and main
and auxiliary hoist functions. The valve solenoids are
controlled electronically through the crane control system
and CANBus system when the controllers in the cab are
actuated. The main DCV is installed and removed as an
assembly.
Main Directional Control Manifold Valve Removal
1.
Tag and disconnect the hydraulic lines from the valve.
Cap or plug the lines and ports.
2.
Tag and disconnect electrical connectors from the valve.
3.
Remove the capscrews, flatwashers, and lockwashers
securing the valve. Remove the valve.
Main Directional Control Manifold Valve Installation
1.
Install the valve on the turntable upright and secure with
the capscrews, flatwashers, and lockwashers. Torque
capscrews. Refer to
1-16 for proper torque value.
2.
Connect the electrical connectors to the valve as tagged
during removal.
3.
Connect the hydraulic lines to the valves as tagged
during removal.
Functional Check
1.
Start the engine and run it at normal speed.
2.
Operate the joysticks of the valve bank(s). Check for
smooth operation of cylinders and motors.
3.
Check the valve bank(s) and lines for leakage. Make
repairs as needed.
Содержание Grove GRT9165
Страница 1: ...Service Manual Grove GRT9165 9897 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 112: ...HYDRAULIC SYSTEM GRT9165 SERVICE MANUAL 2 70 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 138: ...ELECTRICAL SYSTEM GRT9165 SERVICE MANUAL 3 26 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 296: ...MAINTENANCE AND LUBRICATION GRT9165 SERVICE MANUAL 9 52 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 301: ......
Страница 302: ......