![Manitowoc Grove GRT9165 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/manitowoc/grove-grt9165/grove-grt9165_service-manual_701207061.webp)
2-19
GROVE
GRT9165 SERVICE MANUAL
HYDRAULIC SYSTEM
2
Published 10-01-2020 Control # 699-00
Troubleshooting
Symptoms and Solutions
Symptom
Probable Cause
Solution
1.
No hydraulic oil
flows in systems.
a.
Low hydraulic oil level.
a.
Check system for leaks. Make repairs
as needed. Fill reservoir.
b.
Reservoir-to-pump
suction
lines
broken or restricted. Air entering at
suction lines. Pump not priming.
b.
Clean, repair, or replace lines as
necessary. Check lines for security,
absence of cracks, and proper
attachment. Tighten, repair, or
replace parts as necessary.
c.
Pump shaft sheared or disengaged.
c.
If drive shaft is damaged or sheared,
remove and repair or replace as
necessary
d.
Internal contamination.
d.
Drain, flush with recommended oil
mixture, then drain and refill system
with recommended hydraulic oil.
2.
Slow response.
a.
Low hydraulic oil level.
a.
Check system for leaks. Make repairs
as needed. Fill reservoir.
b.
Hydraulic oil temperature too high
(watery thin oil) or too low (thick
sluggish oil).
b.
If too low, warm up system. As
needed, troubleshoot cooler circuit. If
too high, troubleshoot cooler circuit.
Likely suspects are in-line check
valve and related hydraulic circuits.
c.
Faulty pump.
c.
Repair or replace pump.
3.
Pump noise
accompanied by
hydraulic oil
foaming in
reservoir.
a.
Low hydraulic oil level.
a.
Check system for leaks. Make repairs
as needed. Fill reservoir.
b.
Excessive engine speed.
b.
Regulate engine speed.
c.
Air entering at suction lines.
c.
Check all lines for security and proper
repair. Tighten, repair, or replace as
needed.
4.
Excessive
pressure buildup.
a.
System relief valve set too high.
a.
Using adequate pressure gauge,
a d j u s t s y s t e m r e l i e f v a l v e a s
necessary.
b.
Restricted pump-to-control
valve supply line.
b.
Clean, repair, or replace line as
necessary.
5.
Specific hydraulic
system (lift, hoist,
telescope, swing)
not working.
a.
Leak in system.
a.
Check system for leaks. Make repairs
as needed. Fill reservoir.
b.
Faulty hydraulic remote control valve.
b.
Adjust or replace valve.
c.
Faulty directional control valve.
c.
Replace valve.
d.
Poorly adjusted control in circuit.
d.
Troubleshoot circuit with schematic.
Adjust hydraulic component per
schematic.
e.
Faulty hydraulic cylinder, motor, or
valve.
e.
Replace faulty component.
Содержание Grove GRT9165
Страница 1: ...Service Manual Grove GRT9165 9897 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 112: ...HYDRAULIC SYSTEM GRT9165 SERVICE MANUAL 2 70 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 138: ...ELECTRICAL SYSTEM GRT9165 SERVICE MANUAL 3 26 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 296: ...MAINTENANCE AND LUBRICATION GRT9165 SERVICE MANUAL 9 52 Published 10 01 2020 Control 699 00 THIS PAGE BLANK ...
Страница 301: ......